Four-year visual, refractive, and contrast sensitivity outcomes after wavefront-guided myopic LASIK using an advanced excimer laser platform.
نویسندگان
چکیده
PURPOSE To evaluate the 4-year visual, refractive, and contrast sensitivity outcomes of wavefront-guided LASIK for the correction of low to moderate myopia using the VISX CustomVue technology (Abbott Medical Optics, Inc., Santa Ana, CA). METHODS This was a prospective study including 255 consecutive eyes of 145 patients (age range: 19 to 55 years) with low to moderate myopia (mean spherical equivalent: -3.36 ± 1.71 diopters [D]) undergoing laser refractive surgery. Wavefront-guided LASIK was performed in all eyes using the VISX STAR S4 IR excimer laser platform and the CustomVue procedure for the ablation profile design. Visual, refractive, and contrast sensitivity changes were evaluated during a 4-year follow-up period. RESULTS Postoperative logMAR uncorrected distance visual acuity was 0.1 or better (20/25 Snellen) in 98.0% and 100% of eyes at 1 and 4 years, respectively. At 4 years postoperatively, mean spherical equivalent was reduced significantly to a mean value of -0.22 ± 0.28 D (P < .01), with 97.3% of eyes with a spherical equivalent within ±0.50 D. The astigmatic power vector component J0 of manifest refraction was also reduced significantly (P < .01). Postoperative logMAR corrected distance visual acuity was 0.0 or better (20/20 Snellen) in 96.1% and 98.8% of eyes at 1 and 4 years, respectively. Improvement in contrast sensitivity was observed in some spatial frequencies between 1 and 4 years postoperatively. No significant correlations were found between 4-year contrast sensitivity and corrected distance visual acuity (0.024 ≤ r ≤ -0.120, P ≥ .06). CONCLUSION Wavefront-guided LASIK using the VISX CustomVue technology provides an effective and predictable correction of low to moderate myopia in the long term, preserving the patient's visual acuity and quality.
منابع مشابه
Visual outcome after correcting the refractive error of large pupil patients with wavefront-guided ablation
PURPOSE To investigate the efficacy and predictability of wavefront-guided laser in situ keratomileusis (LASIK) treatments using the iris registration (IR) technology for the correction of refractive errors in patients with large pupils. SETTING Horus Vision Correction Center, Alexandria, Egypt. METHODS Prospective noncomparative study including a total of 52 eyes of 30 consecutive laser re...
متن کاملLong-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite
PURPOSE The evaluation of the safety, efficacy, and long-term stability of LASIK procedures utilizing novel platform comprising a femtosecond and excimer laser and multiple networked diagnostics. SETTING Private clinical ophthalmology practice. PATIENTS AND METHODS In consecutive cases of myopic LASIK procedure with a novel refractive platform (FS200 Femtosecond and EX500 Excimer Laser), 19...
متن کاملOutcomes of topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia in virgin eyes.
PURPOSE To compare the outcomes of topography-guided and wavefront-optimized treatment in patients having laser in situ keratomileusis (LASIK) for myopia. SETTING Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India. DESIGN Prospective contralateral-eye case study. METHODS Patients had topography-guided LASIK in 1 eye and wavefront-optimized LA...
متن کاملVisual outcomes after wavefront-guided photorefractive keratectomy and wavefront-guided laser in situ keratomileusis: Prospective comparison.
PURPOSE To compare visual outcomes between wavefront-guided photorefractive keratectomy (PRK) and wavefront-guided laser in situ keratomileusis (LASIK). SETTING Academic center, Salt Lake City, Utah, USA. METHODS In this randomized prospective study, myopic eyes were treated with wavefront-guided PRK and or wavefront-guided LASIK using a Visx Star S4 CustomVue platform with iris registratio...
متن کاملOptical ray tracing-guided myopic laser in situ keratomileusis: 1-year clinical outcomes
PURPOSE To compare the safety, efficacy, and predictability of laser in situ keratomileusis treatments at 1 year postprocedure using a novel geometric ray tracing algorithm with outcomes of treatments using wavefront-optimized, wavefront-guided, and topography-guided ablation profiles of an excimer laser (WaveLight GmbH, Erlangen, Germany; Alcon Laboratories, Fort Worth, TX, USA). SETTING Wel...