Preliminary Investigations of the Contribution of Scatter Radiation During Calibration of TLD-100 Using a Cs-137 Panoramic Source
نویسندگان
چکیده
Studies were carried out to determine the contribution of secondary photons to the calibration set-up of a Secondary Standard Dosimetry Laboratory. In these studies the response of LiF:Mg TLD-100 to known exposures using Cs-137 panoramic-source were investigated. Each TLD chip showed a linear dose response to radiation, demonstrating a typical characteristic of LiF:Mg chips. Whilst TLDs showed an acceptable response range for radiation protection purposes, the percentage differences observed were higher. The relative response values ranged from 0.91 to 1.52. These values indicated the presence of scatter contributing to the exposures. While a contribution of 28.1% was contributed to an exposure of 1 mSv and 48.3% being added to an exposure of 2 mSv, the integrity of the calibration TLDs used for personnel monitoring may not be justified. The set-up may be used for calibrating dosimeters with correction for scattered photons and collimating the beam from the Cs-137 source.
منابع مشابه
Assessment Of The Effectiveness Of Collimation Of Cs–137 Panoramic Beam On Tld Calibration Using A Constructed Lead Block Collimator And An ICRU Slab Phantom At SSDL In Ghana
The objective of calibrating TLD badges and radiation survey meters demand that accurate dose gets to the TLDs and radiation survey meters. A lead block mould and an ICRU slab phantom had been designed and constructed to collimate the panoramic Cs-137 source at the secondary standards dosimetry laboratory (SSDL) by experts at the National Nuclear Research Institute (NNRI) workshop of the Ghana ...
متن کاملDosimetry of Occupational Radiation around Panoramic X-ray Apparatus
Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).<br ...
متن کاملImprovement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...
متن کاملInvestigation of LiF, Mg and Ti (TLD-100) Reproducibility
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...
متن کاملInvestigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code
Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...
متن کامل