Results of a CIE Detector Response Intercomparison1
نویسندگان
چکیده
A total of fifteen laboratories participated in the CIE detector response in-tercomparison which was designed to assess the level of agreement among participating laboratories in the absolute measurement (with respect to SI) of photodetector response in the visible spectral region. Most participants were either commercial laboratories or university laboratories with the National Institute of Standards and Technology (NIST) serving as the host laboratory. Each laboratory determined the absolute response of each of two silicon photodi-ode radiometers which were designed for the intercomparison by NIST. Approximately two-thirds of the laboratories reported response values which agreed with the NIST values to within ±1.0% at the two wavelengths of 488 and 633 nm.^
منابع مشابه
Correlation Between Scanner Response and CIE Tristimulus Values
In this study, a relationship between scanner response (RGB) and CIE tristimulus values (XYZ) is established by regression technique with different polynomials for colored polyester fabrics. The results showed that the transformation process is material dependent and higher order polynomials will fit the experimental data better than lower polynomials. The results also showed that the way the c...
متن کاملCorrelation Between Scanner Response and CIE Tristimulus Values
In this study, a relationship between scanner response (RGB) and CIE tristimulus values (XYZ) is established by regression technique with different polynomials for colored polyester fabrics. The results showed that the transformation process is material dependent and higher order polynomials will fit the experimental data better than lower polynomials. The results also showed that the way the c...
متن کاملPhoton dosimetry based on selective data sampling for the NaI(TL) detector
Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...
متن کاملCollimator-detector response compensation in molecular SPECT reconstruction using STIR framework
Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT. In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کامل