Metal-on-metal joint bearings and hematopoetic malignancy
نویسندگان
چکیده
This is a review of the hip arthroplasty era. We concentrate on new metal bearings, surface replacements, and the lessons not learned, and we highlight recent reports on malignancies and joint implants. A low incidence of blood malignancies has been found in bone marrow taken at prosthetic surgery. The incidence is increased after replacement with knee implants that release very low systemic levels of metal ions. A carcinogenic effect of the high levels of metal ions released by large metal-on-metal implants cannot be excluded. Ongoing Swedish implant registry studies going back to 1975 can serve as a basis for evaluation of this risk.
منابع مشابه
Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.
This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bear...
متن کاملA simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings
OBJECTIVES Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt-chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA). METHODS Cement flakes (PMMA), CoCr a...
متن کاملMetal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing.
Introduction etal-on-metal bearings for hip replacement are gaining popularity as an alternative to the most widely used bearing couple of metal on polyethylene. The recent resurgence of hip resurfacing with the socalled third and fourth generations of hip resurfacing arthroplasty devices has played a substantial role in the wider use of metal-on-metal bearings. Concerns about the wear of polye...
متن کاملPerfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study.
OBJECTIVES Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI ...
متن کاملDislocation after total hip replacement in relation to metal-on-metal bearing surfaces.
Metal-on-metal (MOM) is a commonly used bearing notable for its 'suction fit' when lubricated. In this study, we examined the capacity for MOM bearings to protect against dislocation after total hip replacement (THR). We undertook a clinical investigation to compare the rate of dislocation of MOM bearings with those of ceramic-on-polyethylene (COP) bearings and found that one MOM bearing disloc...
متن کامل