The effect of some fluids on surface oxidation and amount of released iron of stainless steel endodontic files.

نویسندگان

  • Mohammad Ali Saghiri
  • Franklin García-Godoy
  • Mehrdad Lotfi
  • Peyman Mehrvazfar
  • Mohsen Aminsobhani
  • Samad Rezaie
  • Kamal Asgar
چکیده

Endodontic files come in contact with blood, infected pulp tissue, and irrigating solutions during root canal therapy. Some instruments such as stereomicroscopy and scanning electron microscopy are used to observe corrosion of endodontic files which are complicated and dependent on preparation methods. Having knowledge of the corrosion and ion release of endodontic files can help in drawing firm deductions as to which files would perform better in the clinical scenario. Therefore, we have used energy dispersive X-ray analysis and an atomic absorption spectrophotometer to track oxygen on the surface and iron in the exposed media to observe the oxidative rate of the media. In this study, corrosion by blood was higher than other biological fluids, but less than with sodium hypochlorite (NaOCl). Observations of energy dispersive X-ray analysis and atomic absorption spectrophotometer results demonstrated that after exposure the amount of oxygen on the surface and surrounding areas increased. Therefore, the files should be rinsed as soon as possible during and after use to hinder the oxidation rate, but blood may produce a different behavior and it might be considered as a decreased risk of broken stainless steel files remaining in the root canal after treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of electroplating parameters on microstructure and amount of ceramic particle deposition in Ni-Co-CeO2-ZrO2 composite coating

Austenitic stainless steels are high performance steels that have various applications in solid oxide fuel cells and boiler tubes under high temperature operating conditions. The Cr2O3 oxide layer formed on the steel surface becomes unstable at high temperatures and reduces the oxidation resistance of the steel. Therefore, protection of these steels at high temperatures is essential. Therefore,...

متن کامل

The Effect of Chloride Ions Concentration on the Electrochemical Behavior of AISI 410 Stainless Steels in Simulated Concrete Pore Solution

The effect of chloride ions concentration on the electrochemical behavior of AISI 410 stainless steel in the simulated concrete pore (0.1 M NaOH + 0.1 M KOH) solution was investigated by various electrochemical methods such as Potentiodynamic polarization, Mott–Schottky analysis and electrochemical impedance spectroscopy (EIS). Potentiodynamic polarization curves revealed that increasing chlori...

متن کامل

The Effect of Surface Treatment on Corrosion behavior of Surgical 316L Stainless Steel Implant

The AISI 316 L Stainless Steel (SS) specimens were exposed to passivation surface through two different processes including; holding in 40-vol% HNO3 at temperature of 60 ºC for 30 min and 15-vol%H2SO4 at ambient temperature for 1 hour. The corrosion behavior of specimens was evaluated in physiological solutions by electrochemical in vitro tests through linear an...

متن کامل

Isothermal and cyclic oxidation behavior of AISI 430 ferritic stainless steel coated with titanium

In order to improve the oxidation resistance of ferritic stainless steel, it is possible to deposit a protective coating on steel substrate. In this research through the usage of pack cementation method a coating of titanium was applied on the surface of AISI 430 stainless steel. Scanning Electron-Microscopy (SEM), Energy- Dispersive X-ray spectrometry (EDAX) and X-ray diffraction (XRD) were us...

متن کامل

EFFECT OF ANODIC OXIDATION ON THE CORROSION BEHAVIOR OF NICKEL-TITANIUM SHAPE MEMORY ALLOYS IN SIMULATED BODY FLUIDS (SBF)

The effect of anodic oxidation of a NiTi shape memory alloy in sulfuric acid electrolyte on its surface characteristics was studied. Surface roughness was measured by roughness tester. Surface morphology was studied using optical microscopy (OM) and scanning electron microscopy (SEM). Corrosion behavior was specified by recording Potentiodynamic polarization cur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Scanning

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2012