Influence of ceramic and stainless steel brackets on the notching of archwires during clinical treatment.

نویسندگان

  • L C Articolo
  • K Kusy
  • C R Saunders
  • R P Kusy
چکیده

The surface topography of 100 clinically used archwires of stainless steel, beta-, or nickel-titanium were investigated that had contacted either ceramic or stainless steel brackets. One group consisted of two sets: 60 wires with no treatment records accessed to bias analyses, and 40 wires for which extensive clinical records were available, half of which were used with ceramic or stainless steel brackets. A control group consisted of two sets: 30 unused wires comprised of five round and rectangular wires of each alloy, and four wires that were ligated and immediately removed from patients' mouths. After ultrasonic cleaning, each wire was inspected under an optical and/or a scanning electron microscope. Notches were categorized with regard to frequency, patterns, and severity, and mapped as a function of wire aspect (lingual, facial, and occlusal/gingival) and anatomical regions (molar, premolar, canine, and incisor). From these data the average severity of notch patterns and a notching index were derived. Although no recognizable defect patterns were observed in the control group, seven basic patterns were recognized for each wire cross-sectional shape in the clinically used wires. These wires appeared most damaged on their lingual aspect and least damaged on their facial aspect. With regard to anatomical regions, notching was prevalent in the anterior regions and sparse in the molar regions. The notch activity and the severity were nearly three times greater from ceramic brackets than from stainless steel brackets. Over one-third of all notches documented in ceramic bracket cases had severity numbers of 3 and penetrated at least one-quarter of each wire's dimension, However, over two-thirds of all notches documented in stainless steel bracket cases had severity numbers of 1. From these tabulations a theory of notch formation was proposed in which vertical movement from tooth or wire during mastication caused fretting wear, and horizontal movement during orthodontic procedures such as space closure, tipping, or bodily movement caused sliding wear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative study of Resistance during Tooth Retraction Using Ceramic Bracket and Ceramic Bracket with Metal Slot: In-Vitro Study

Frictional resistance is an important counterforce to orthodontic tooth movement during sliding mechanics. This study was carried out to evaluate the effect of ceramic bracket and ceramic bracket with metal slot -archwire‐ ligation combinations on “resistance to sliding” during simulated canine retraction on typodont model. The frictional resistance was tested between Ceramic brackets (3MUNITEK...

متن کامل

Comparative Evaluation of Frictional forces between different Archwire-bracket Combinations

Introduction: During sliding mechanics, frictional resistance is an important counterforce to orthodontic tooth movement; which must be controlled to allow application of light continuous forces. objective: To investigate static and kinetic frictional resistance between three orthodontic brackets: ceramic, self-ligating, and stainless steel, and three 0.019×0.025” archwires: stainless steel, ni...

متن کامل

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group ...

متن کامل

In vitro evaluation of frictional forces between archwires and ceramic brackets.

The aim of this study was to evaluate the frictional force between orthodontic brackets and archwires. The differences in magnitude of the frictional forces generated by ceramic brackets, ceramic brackets with metal reinforced slot, and stainless steel brackets in combination with stainless steel, nickel-titanium, and beta-titanium orthodontic archwires were investigated. Brackets and wire were...

متن کامل

Evaluation of friction of conventional and metal-insert ceramic brackets in various bracket-archwire combinations.

The purpose of the study was to measure and compare the level of frictional resistance generated between conventional ceramic brackets (Transcend Series 6000, 3M Unitek, Monrovia, Calif), ceramic brackets with stainless steel slot (Clarity, 3M Unitek), conventional stainless steel brackets (Victory Series, 3M Unitek), and 3 different orthodontic wire alloys: stainless steel (stainless steel, SD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 2000