Clinical and radiological outcome following total hip arthroplasty with an uncemented trabecular metal monoblock acetabular cup.

نویسندگان

  • Baskaran Komarasamy
  • Ramanan Vadivelu
  • Andrew Bruce
  • Christopher Kershaw
  • John Davison
چکیده

Uncemented acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. The new tantalum/polyethylene composite (Hedrocel) acetabular component is designed to reduce the polyethylene wear and to increase the longevity of the acetabular cups. We report our short- term clinical outcome and patient satisfaction following use of an uncemented tantalum acetabular component in a single centre. During 1999 to 2002, 113 uncemented tantalum acetabular cups were implanted in 105 patients in our institution. The average age at operation was 56.8 years. All patients were assessed pre- and post-operatively with the Oxford 12 item hip questionnaire and standard radiographs of the pelvis. At a mean follow-up of 32 months (range: 18 to 48), 112 Hedrocel cups were assessed in 104 patients. Subjective patient's satisfaction was also assessed. At the time of evaluation, one patient had died due to an unrelated cause. Eight patients had bilateral acetabular cups implanted. The mean Oxford hip score improved from 45 preoperatively to 14 post-operatively. Subjectively 99% were very satisfied or satisfied. Only one patient expressed dissatisfaction about the outcome of this surgery. Radiologically, there were no signs of cup loosening or wear. This study shows that at short-term the new uncemented tantalum/polyethylene composite (Hedrocel) acetabular component can yield a satisfactory clinical and radiological outcome and has a high patient satisfaction. Although the short-term result from our centre is very encouraging, similar results from other centres and longer follow-up are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty

BACKGROUND Trabecular metal has shown promising results in experimental studies of bone ingrowth. Several clinical studies support these results. However, until now, no randomized clinical radiostereometric analysis (RSA) studies have been published. In this randomized RSA trial, we compared a new acetabular cup with a surface made of tantalum trabecular metal and a cup with a titanium fiber-me...

متن کامل

Radiological evaluation of the metal-bone interface of a porous tantalum monoblock acetabular component.

Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component...

متن کامل

Survival of uncemented acetabular monoblock cups

BACKGROUND AND PURPOSE Monoblock acetabular cups represent a subtype of uncemented cups with the polyethylene liner molded into a metal shell, thus eliminating-or at least minimizing-potential backside wear. We hypothesized that the use of monoblock cups could reduce the incidence of osteolysis and aseptic loosening, and thus improve survival compared to modular designs. PATIENTS AND METHODS ...

متن کامل

Early results of trabecular metal augment for acetabular reconstruction in revision hip arthroplasty.

The management of acetabular bone defects presents a challenge in revision total hip arthroplasty (THA). The aim of this study was to assess the early clinical and radiological outcome of revision of acetabular components using trabecular metal cups and augments for acetabular reconstruction. The study included 18 consecutive patients with failed acetabular components after total hip arthroplas...

متن کامل

Acetabular Cup Revision

The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an importa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 72 3  شماره 

صفحات  -

تاریخ انتشار 2006