B1-insensitive T2 mapping of healthy thigh muscles using a T2-prepared 3D TSE sequence
نویسندگان
چکیده
PURPOSE To propose a T2-prepared 3D turbo spin echo (T2prep 3D TSE) sequence for B1-insensitive skeletal muscle T2 mapping and compare its performance with 2D and 3D multi-echo spin echo (MESE) for T2 mapping in thigh muscles of healthy subjects. METHODS The performance of 2D MESE, 3D MESE and the proposed T2prep 3D TSE in the presence of transmit B1 and B0 inhomogeneities was first simulated. The thigh muscles of ten young and healthy subjects were then scanned on a 3 T system and T2 mapping was performed using the three sequences. Transmit B1-maps and proton density fat fraction (PDFF) maps were also acquired. The subjects were scanned three times to assess reproducibility. T2 values were compared among sequences and their sensitivity to B1 inhomogeneities was compared to simulation results. Correlations were also determined between T2 values, PDFF and B1. RESULTS The left rectus femoris muscle showed the largest B1 deviations from the nominal value (from 54.2% to 92.9%). Significant negative correlations between T2 values and B1 values were found in the left rectus femoris muscle for 3D MESE (r = -0.72, p<0.001) and 2D MESE (r = -0.71, p<0.001), but not for T2prep 3D TSE (r = -0.32, p = 0.09). Reproducibility of T2 expressed by root mean square coefficients of variation (RMSCVs) were equal to 3.5% in T2prep 3D TSE, 2.6% in 3D MESE and 2.4% in 2D MESE. Significant differences between T2 values of 3D sequences (T2prep 3D TSE and 3D MESE) and 2D MESE were found in all muscles with the highest values for 2D MESE (p<0.05). No significant correlations were found between PDFF and T2 values. CONCLUSION A strong influence of an inhomogeneous B1 field on the T2 values of 3D MESE and 2D MESE was shown, whereas the proposed T2prep 3D TSE gives B1-insensitive and reproducible thigh muscle T2 mapping.
منابع مشابه
Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion
BACKGROUND Several T2-mapping sequences have been recently proposed to quantify myocardial edema by providing T2 relaxation time values. However, no T2-mapping sequence has ever been validated against actual myocardial water content for edema detection. In addition, these T2-mapping sequences are either time-consuming or require specialized software for data acquisition and/or post-processing, ...
متن کاملDetecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study
Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the e...
متن کاملThe Accuracy of Myocardial T2-Mapping Techniques
Objective: 1. To evaluate different pulse sequence options available for T2 Mapping of human myocardium vis-à-vis accuracy of T2 measurements in phantoms. 2. To propose a practical approach to T2 evaluation that can be used in clinical setting to distinguish tissues with T2 differences 3. To get a range of values for human myocardial T2 values using the most accurate and practical approach. 4. ...
متن کاملSpectrally Selective B1 Insensitive T2 Preparation Sequence for 3T Imaging
R. Nezafat, J. A. Derbyshire, R. Ouwerkerk, M. Stuber, E. R. McVeigh Lab of Cardiac Energetics, Division of Intramural Research, NHLBI, NIH, DHHS, Bethesda, MD, United States, Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States, Radiology, Johns Hopkins University, Baltimore, MD, United States Introduction: T2 magnetization preparation (T2 Prep) and spectrally selecti...
متن کاملMagic angle effect: a relevant artifact in MR neurography at 3T?
BACKGROUND AND PURPOSE MRN is an emerging diagnostic method for disorders of peripheral nerves. However, it is unclear whether the influence of the MA on intraneural T2 signal is severe enough to provoke false-positive findings. MATERIALS AND METHODS Twenty-five healthy subjects underwent MRN of the sciatic nerve of the proximal thigh at 3T. The T2(app) was calculated from a DE-TSE sequence (...
متن کامل