Treatment Planning With Unflattened as Compared to Flattened Beams for Bilateral Carcinoma of the Breast

نویسندگان

  • Suresh Tamilarasu
  • Madeswaran Saminathan
  • S K Sharma
  • Anjali P
  • Abhinav Dewan
چکیده

Aim: To evaluate the plan quality of 6MV unflattened (UFB) and flattened beam (FB) photon energy using AAA dose calculation algorithms for volumetric arc therapy. Materials and Methods: Plans were generated for bilateral carcinoma of breast and the dose prescribed was 50.4Gy in 28 fractions. Two different plans were made for each patient using 6MV FB and 6MV UFB. Dose calculations were performed on an AAA dose calculation algorithm. Plans were generated on Eclipse TPS and were capable of being delivered with a true beam STx linear accelerator. The homogeneity index (HI), conformity index (CI), normal tissue integral dose (NTID), and effect of low dose volume on normal tissue and monitor units (MU) were noted. Results: All the plans were clinically acceptable. The HI and CI of 6MV UF rapid arc (RA) plans were higher than with the 6MV FB plan (1.16±0.05 and 0.12±0.00 respectively). There was no appreciable difference observed in Organ at risk (OAR) doses. The mean NTID and low dose volume were significantly low with 6MV RA UFB as compared to FB. 6MV RA UFB required a 35% higher MU than with the 6MV RA plan (p<0.05). Conclusion: RA plans generated with UFB on Eclipse TPS achieved target volume coverage and preserved OAR’s essentially similar to 6MV RA FB plans. However RA plans generated in Varian Eclipse of UFB were superior with respect to mean NTID and low dose volumes in normal tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...

متن کامل

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac

The objective of this study was to assess the feasibility of stereotactic radiotherapy for early stage lung cancer using photon beams from a Varian Clinac accelerator operated without a flattening filter. Treatment plans were generated for 10 lung cancer patients with isolated lesions less than 3 cm in diameter. For each patient, two plans were generated, one with and one without the flattening...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Comparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy

Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017