Lactate analyzer with continuous blood sampling for monitoring blood lactate during physical exercise.
نویسندگان
چکیده
To monitor changes in the concentration of blood lactate during physical exercise, we used an automated lactate analyzer based on an electro-enzymatic method with continuous blood sampling through a catheter. The lactate concentration was measured every 2 min; between measurements, the instrument was calibrated with a lactate standard. Ascorbic acid, bilirubin, hemoglobin, creatinine, uric acid, and glucose did not interfere with the measurements. The lactate concentrations in blood samples from apparently healthy subjects before and after exercise correlated well (r = 0.993) with results by the conventional enzymatic method. We measured the blood lactate concentrations in nine apparently healthy volunteers during exercise on a treadmill with an increasing workload. The point at which lactate concentrations started to increase was detected easily. Thus, the lactate analyzer is suitable for monitoring changes in blood lactate concentrations during exercise.
منابع مشابه
The effects of using bench press and leg curl resistance exercise during rest interval on rating of perceived exertion, blood lactate and quantity of leg extension performance in bodybuilders
The purpose of this study was to investigate the effects of using upper (Bench press) and lower body (Leg curl) exercise during rest interval on rating of perceived exertion (RPE), lactate production and quantity of lower body performance (Leg extension) with 75% 1RM (repetition maximum). 15 resistance trained men (age 20.9±1.9 years, height 175.6 ±4.5 cm and weight 74.8±5.2 kg) took part in fo...
متن کاملSimple Lactate Measurement in Horses Using a Portable Lactate Analyzer with Lancet Skin Punctures under Field Conditions
J. Equine Sci. Vol. 18, No. 1 pp. 5–11, 2007 The following items were investigated to measure blood lactate in horses under field conditions using portable lactate analyzers recently developed for human athletes. 1) The precision of two types of portable lactate analyzer and the standard analyzer using the immobilized enzyme method, and correlation among the lactate concentrations measured by t...
متن کاملThe Effect of leech therapy on Blood Lactate Level and Pain Perception Index in Athletes following an Exhausting Physical Activity
Background & Aim: Leech Therapy is a type of complementary and alternative medicine that has been used for a long time as a therapeutic method in traditional Iranian Islamic medicine. The purpose of this study was to investigate the effect of leech therapy on blood lactate level and pain perception index following an Exhausting Physical activity in young male athletes. Methods: Sixteen athlete...
متن کاملA method-comparison study regarding the validity and reliability of the Lactate Plus analyzer
OBJECTIVES The aims of this study were to: (1) determine the validity and reliability of the Nova Biomedical Lactate Plus portable analyzer, and quantify any fixed or proportional bias; (2) determine the effect of any bias on the determination of the lactate threshold and (3) determine the effect that blood sampling methods have on validity and reliability. DESIGN In this method comparison st...
متن کاملAcute Effects of Two Energy Drinks on Anaerobic Power and Blood Lactate & PH Recovery in Male Athletes
In order to compare the acute effects of OR and Megabasic (two energy drinks) by a placebo, 24 volunteer male athletes (age: 24.3±2.03 yrs, height 173.56±7.02cm and weight 75.43±3.07kg) participated in two consecutive RAST tests by 40 min rest interval in between within 3 randomly divided groups. There were six times blood sampling (before and also 2 and 4 min after than both tests) in ord...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 37 11 شماره
صفحات -
تاریخ انتشار 1991