Recording Cortical EEG Subcortically — Improved EEG Monitoring from Depth-Stimulation Electrodes

نویسندگان

  • Katrina Wendel
  • Kalervo Suominen
  • Pasi Kauppinen
  • Eila Sonkajärvi
  • Jarno M. A. Tanskanen
  • Kotoe Kamata
  • Outi Väisänen
  • Jari Hyttinen
  • Ville Jäntti
چکیده

The electroencephalogram (EEG) generated by cerebral cortex can be recorded far away from the cortex, analogous to the electrocardiogram (ECG) that can be recorded far from the heart. ECG is often seen as an artifact in EEG recordings. In this paper we demonstrate that the burst suppression pattern of EEG, which is generated by the cerebral cortex, can be recorded at a distance from the cortex with a pair of electrodes in the subthalamic nucleus and also with an electrode pair on the masseter muscle below the zygomatic arch. We then present a fundamental theoretical model which explains the currents inside and outside the cranium, which produce the EEG at these locations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O16: Long Term Video EEG (AC/DC) Monitoring

Long term video electro-encephalographic (EEG) monitoring (LTM) is defined as the continuous and synchronized recording of EEG and multimedia to analyze brain abnormalities. A conventional LTM system continuously records EEG in the frequency range of 0.5-70Hz. The data synchronization, the high-volume data management, the system reliability as well as noise reduction remain significant challeng...

متن کامل

Electroencephalographic recording during transcranial magnetic stimulation in humans and animals.

OBJECTIVE We report on the development of an EEG recording system, comprised of electrodes and amplifiers that are compatible with TMS (single and rapid-rate) in both human and animal studies. METHODS We assembled a versatile multi-channel EEG recording system consisting of: (1) two types of electrodes that are safe during TMS or rTMS. (2) Low slew-rate EEG amplifiers that recover within a fe...

متن کامل

Arousal of cerebral cortex electroencephalogram consequent to high-frequency stimulation of ventral medullary reticular formation.

We have theorized that large neurons in the ventral and medial reticular formation of the medulla are critical for both autonomic and cortical arousal. To test this theory, we anesthetized rats with urethane, lowered concentric bipolar stimulating electrodes into the medullary reticular formation, and implanted electroencephalogram (EEG) and ECG recording electrodes. We stimulated in the medull...

متن کامل

Correlation of invasive EEG and scalp EEG

Ever since the implementation of invasive EEG recordings in the clinical setting, it has been perceived that a considerable proportion of epileptic discharges present at a cortical level are missed by routine scalp EEG recordings. Several in vitro, in vivo, and simulation studies have been performed in the past decades aiming to clarify the interrelations of cortical sources with their scalp an...

متن کامل

Transcranial magnetic stimulation and cortical evoked potentials: a TMS/EEG co-registration study.

OBJECTIVE In recent years, a promising tool has been introduced which allows the co-registration of electroencephalographic (EEG) activity during brain transcranial magnetic stimulation (TMS). The aims of the present study are to identify eventual stimulus-related artefacts, and to confirm and extend previous EEG/TMS findings about the possible networks generating EEG responses evoked by TMS. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011