Single-centre experience on endocardial and epicardial pacemaker system function in neonates and infants.

نویسندگان

  • Massimo Stefano Silvetti
  • Fabrizio Drago
  • Antonella De Santis
  • Giorgia Grutter
  • Lucilla Ravà
  • Lidia Monti
  • Rodolfo Fruhwirth
چکیده

AIMS Endocardial (ENDO) or epicardial (EPI) pacing systems are implanted in infants but it remains unclear which system should be preferred. METHODS AND RESULTS We evaluated the results of children <or=1 year who underwent pacemaker (PM) implantation at our centre with a retrospective analysis. Between 1992 and 2004, 56 patients, 37 of whom had other congenital heart defects (CHDs), received a PM at 4.4 +/- 3.8 months of age for atrioventricular block (n = 52) and sinus node dysfunction. Rate-responsive ventricular demand pacing (VVIR) PMs were implanted in 25 patients (19 ENDO), dual-chamber demand pacing (DDD) in 29, and rate-responsive atrial demand pacing (AAIR) in 2 (all EPI). Follow-up (FU) was 4.5 +/- 3.5 (range 0.3-13) years: 15 pacing system failures occurred among the 56 patients (26%) after 4.5 +/- 3.2 years, with a significantly reduced success rate for EPI (21-fold increase of the risk of failure) and complex CHD. Also in patients without surgery for CHD, EPI showed a worse outcome. Among the 91 leads implanted, failures occurred more significantly in EPI (18% of atrial, 24% of ventricular leads) than in ENDO (5% of ventricular leads). No venous occlusion was found at FU. CONCLUSIONS Single-lead, VVIR ENDO pacing had higher efficiency and safety than EPI, and it might be the best choice for PM implantation in infants. However, because of small patient numbers and lack of longer FU, these findings should be treated with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endocardial Pacemaker Implantation in Neonates and Infants

Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation te...

متن کامل

Equivalent performance of epicardial versus endocardial permanent pacing in children: a single institution and manufacturer experience.

BACKGROUND Children requiring permanent pacing have a lifelong need for follow-up. Epicardial leads have traditionally fared worse than endocardial counterparts. We tested the hypothesis that steroid-eluting epicardial and endocardial leads had equivalent outcomes. METHODS We reviewed medical records of 148 children, mean age 8.2 +/- 4.8 years, in whom a dual-chamber pacemaker system with ste...

متن کامل

Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

BACKGROUND Epicardial pacemaker implantation is the favored approach in children weighing <10 kg in many units. The high incidence of premature failure and fractures with earlier epicardial leads led our unit to undertake transvenous pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. ME...

متن کامل

Frequency of Congenital Cardiac Malformations in the Neonates with Congenital Hypothyroidism

Background: Congenital hypothyroidism (CH) is a prevalent disorder, which is associated with several other congenital anomalies, especially cardiac diseases. The present study aimed to determine the prevalence of congenital heart disease (CHD) in the neonates with CH.Methods: This cross-sectional study was conducted on two groups of 79 subjects to compare the type and frequency of congenital ca...

متن کامل

Long term results of permanent epicardial pacing in neonates and infants

Method From 1989 to 2013, 44 patients (15 neonates) underwent pacemaker implantation within the first year of life. The mean age and weight were 101.2 ± 97.2 days and 4.8 ± 1.8kg at the time of pacemaker implantation. The Indication for pacemaker implantation were postoperative atrioventricular block in 23, congenital atrioventricular block in 16, sinus node dysfunction in 4, and myocarditis in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 2007