N ov 2 00 2 Multi - energy radiography on the basis of “ scintillator - photodiode ” detectors

نویسندگان

  • S. V. Naydenov
  • V. D. Ryzhikov
  • B. V. Grinyov
  • E. K. Lisetskaya
  • D. N. Kozin
چکیده

For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintil-lators ZnSe(T e) and CsI(T l).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

x / 02 06 01 8 v 1 1 0 Ju n 20 02 Multi - energy radiography on the basis of “ scintillator - photodiode ” detectors

For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintil-lators ZnSe(T e) and CsI(...

متن کامل

5 J un 2 00 6 Scintillator counters with multi - pixel avalanche photodiode readout for the ND 280 detector of the T 2 K experiment

The Tokai–to–Kamioka (T2K) experiment is a second generation long baseline neutrino oscillation experiment which aims at a sensitive search for the νe appearance. The main design features of the T2K near neutrino detectors located at 280 m from the target are presented. Scintillator counters developed for the T2K near detectors are described. Readout of the counters is provided via WLS fibers e...

متن کامل

Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code

Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...

متن کامل

Pii: S0720-048x(98)00109-0

Objecti6e: The performance of medical X-ray image receptors depends: (1) on the scintillator light emission efficiency; and (2) on the compatibility of the scintillator light spectrum with the spectral sensitivity of the light detector (film, photocathode, or photodiode), employed in conjunction with the scintillator. In this study, a scintillator performance measure, the effective fidelity ind...

متن کامل

2 00 9 Scintillator counters with WLS fiber / MPPC readout for the side muon range detector ( SMRD ) of the T 2 K experiment

The T2K neutrino experiment at J-PARC uses a set of near detectors to measure the properties of an unoscillated neutrino beam and neutrino interaction cross-sections. One of the sub-detectors of the near-detector complex, the side muon range detector (SMRD), is described in the paper. The detector is designed to help measure the neutrino energy spectrum, to identify background and to calibrate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002