Development of a decision-analytic model for the application of STR-based provenance testing of transrectal prostate biopsy specimens.

نویسندگان

  • John D Pfeifer
  • Michael N Singleton
  • Martin H Gregory
  • Dennis L Lambert
  • Steven M Kymes
چکیده

BACKGROUND The diagnostic algorithm for most cancers includes the assessment of a tissue specimen by a surgical pathologist, but if specimen provenance is uncertain, the diagnostic and therapeutic process carries significant risk to the patient. Over the last decade, short tandem repeat (STR) analysis has emerged as a DNA-based method with clinical applicability for specimen identity testing (also known as specimen provenance testing). Although the clinical utility of identity testing using STR-based analysis has been demonstrated in many studies, its economic value has not been established. METHODS We developed a decision-analytic model of the application of STR-based provenance testing of transrectal prostate biopsy specimens obtained as part of routine clinical care to rule out the presence of adenocarcinoma of the prostate, as compared with no STR-based testing. Using parameter values drawn from the published literature, the cost-effectiveness of STR-based testing was quantified by calculating the incremental cost-effectiveness ratio per quality-adjusted life-year gained. RESULTS In comparison to the current standard practice of no identity testing, identity testing by STR-based analysis has an incremental cost-effectiveness ratio of $65,570 per quality-adjusted life-year gained at a testing cost of $618 per person. At a cost of $515 per person, identity testing would meet the conservative standard of $50,000 per quality-adjusted life-year. At a test cost of $290 per person, identity testing would be cost saving. CONCLUSION Given the rapidly declining pricing of STR-based identity testing, it is likely that testing to confirm the identity of positive prostate biopsy samples will be a cost-effective method for preventing treatment errors stemming from misidentification. Studies to formally establish the frequency of specimen provenance errors in routine clinical practice would therefore seem justified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exploring the Effect of PSA Density and Prostate Size on Concordance of TRUS Biopsy Result with Radical Prostatectomy

Background and Objective: Today’s, the Gleason grading system is well known as the world’s most commonly used histological system for prostate cancer. It provides significant information about the prognosis. This prospective paper assessed the correlation of transrectal ultrasound (TRUS) guided biopsy and radical prostatectomy specimens in terms of Gleason scores. In this matter, the effect of ...

متن کامل

Endothelin-1 expression in prostate needle biopsy specimens correlated with aggressiveness of prostatic cancer

Background & Objective: As the prostate adenocarcinoma is one of the most common malignant tumors in males, looking for a marker to effectively predict aggressiveness and metastatic potential in an apparently localized cancer in initial needle biopsy specimens can help the clinicians to make more appropriate decision for treatment, planning, and choosing appropriate ta...

متن کامل

Prognostic Value of Neutrophil to Lymphocyte Ratio on Pathologic Findings of Transrectal Ultrasonography Guided Biopsy of Prostate

Background and Objective: Prostate cancer is considered as one of the most common malignancies in males. Despite the decreasing trend during the past decade, the incidence continues to rise in adolescents worldwide. Recently, new emerging technologies beside TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. The current st...

متن کامل

Application of Bland-Altman Method in Comparing Transrectal and Transabdominal Ultrasonography for Estimating Prostate Volume

Background: Estimating prostate volume using less invasive transabdominal ultrasonography (TAUS) instead of transrectal ultrasonography (TRUS) is of interest in terms of identifying their agreement level. Previous reports on this subject, applied general correlation coefficient as the level of agreement. This study uses Bland-Altman method to quantify TAUS and TRUS agreement on estimating prost...

متن کامل

Differentiation Of Granulomatous Prostatitis From Prostate Carcinoma

  Background and Objective: Non-specific granulomatous prostatitis is an uncommon diffuse inflammatory condition of the prostate. It is important because it may be mistaken for prostatic carcinoma. The aim of the study was to determine the prevalence of non-specific granulomatous prostatitis (NSGP) and comparing the results of transrectal ultrasonography, serum prostate specific antigen (PSA) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Value in health : the journal of the International Society for Pharmacoeconomics and Outcomes Research

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2012