Accelerated tomotherapy delivery with TomoEdge technique
نویسندگان
چکیده
TomoEDGE is an advanced delivery form of tomotherapy which uses a dynamic secondary collimator. This plan comparison study describes the new features, their clinical applicability, and their effect on plan quality and treatment speed. For the first 45 patients worldwide that were scheduled for a treatment with TomoEdge, at least two plans were created: one with the previous "standard"mode with static jaws and 2.5 cm field width (Reg 2.5) and one with TomoEdge technique and 5 cm field width (Edge 5). If, after analysis in terms of beam on time, integral dose, dose conformity, and organ at risk sparing the treating physician decided that the Edge 5 plan was not suitable for clinical treatment, a plan with TomoEdge and 2.5 cm field width was created (Edge 2.5) and used for the treatment. Among the 45 cases, 30 were suitable for Edge 5 treatment, including treatments of the head and neck, rectal cancer, anal cancer, malignancies of the chest, breast cancer, and palliative treatments. In these cases, the use of a 5 cm field width reduced beam on time by more than 30% without compromising plan quality. The 5 cm beam could not be clinically applied to treatments of the pelvic lymph nodes for prostate cancer and to head and neck irradiations with extensive involvement of the skull, as dose to critical organs at risk such as bladder (average dose 28 Gy vs. 29 Gy, Reg 2.5 vs. Edge 5), small bowel (29% vs. 31%, Reg 2.5 vs. Edge 5) and brain (average dose partial brain 19 Gy vs. 21 Gy, Reg 2.5 vs. Edge 5) increased to a clinically relevant, yet not statistically significant, amount. TomoEdge is an advantageous extension of the tomotherapy technique that can speed up treatments and thus increase patient comfort and safety in the majority of clinical settings.
منابع مشابه
Fast Helical Tomotherapy in a head and neck cancer planning study: is time priceless?
BACKGROUND The last few years, in radiotherapy there has been a growing focus on speed of treatment delivery (largely driven by economical and commercial interests). This study investigates the influence of treatment time on plan quality for helical tomotherapy (HT), using delivery times with Volumetric Modulated Arc Therapy (VMAT; Rapid Arc [RA]) as reference. METHODS In a previous study, do...
متن کاملImplementation of TomoEDGE in the independent dose calculator CheckTomo
PURPOSE CheckTomo is an independent dose calculation software for tomotherapy. Recently, Accuray (Accuray Inc., Sunnyvale, CA, USA) released an upgrade of its tomotherapy treatment device, called TomoEDGE Dynamic Jaws, which improves the quality of treatment plans by enhancing the dose delivery with the help of jaws motion. This study describes the upgrade of CheckTomo to that new feature. ME...
متن کاملEvaluation of the optimal combinations of modulation factor and pitch for Helical TomoTherapy plans made with TomoEdge using Pareto optimal fronts
BACKGROUND Modulation factor (MF) and pitch have an impact on Helical TomoTherapy (HT) plan quality and HT users mostly use vendor-recommended settings. This study analyses the effect of these two parameters on both plan quality and treatment time for plans made with TomoEdge planning software by using the concept of Pareto optimal fronts. METHODS More than 450 plans with different combinatio...
متن کاملReal-time motion-adaptive-optimization (MAO) in TomoTherapy.
IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for intra-fraction motion. Specifically, we developed a feasible workflow of real-t...
متن کاملEvaluation of two tomotherapy-based techniques for the delivery of whole-breast intensity-modulated radiation therapy.
PURPOSE To evaluate two different techniques for whole-breast treatments delivered using the Hi-ART II tomotherapy device. METHODS AND MATERIALS Tomotherapy uses the standard rotational helical delivery. Topotherapy uses a stationary gantry while delivering intensity-modulated treatments. CT scans from 5 breast cancer patients were used. The prescription dose was 50.4 Gy. RESULTS On average...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2015