Tongue oximetry in children with extensive thermal injury: comparison with peripheral oximetry.
نویسندگان
چکیده
We undertook a prospective study of standard peripheral pulse oximetry versus a modified pulse oximeter probe applied to the tongue in order to determine the efficacy of this alternative monitoring site in children with thermal injuries. Ten patients with a mean age (+/- SD) of 7.5 +/- 4.5 yr were studied on 15 occasions. The mean weight (+/- SD) was 31.4 +/- 13.7 kg and percent surface area burn (+/- SD) was 56 +/- 21%. A total of 1,992 min of anaesthesia time was monitored. Both sites functioned simultaneously 47% of the time; the lingual but not the peripheral site functioned 28% of the time and only the peripheral site and not the lingual functioned 22% of the time. Neither site functioned 3% of the time. The tongue oximeter provided 563 min more monitoring time than the peripheral sites. The tongue oximeter also functioned in children with peripheral vasoconstriction when the peripheral sensor failed and was less susceptible to electrocautery interference. The tongue oximeter is a reasonable adjunct but not a substitute for peripheral oximetry since its application is limited to paralyzed, intubated patients.
منابع مشابه
Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns
Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...
متن کاملAnaesthesia and the Amazon.
measurements under these conditions, Jobes and Nicolson ~ modified an oximetry probe for attachment to the tongue. Gunter 2 found this technique difficult to use since the modified probe kept slipping off. He adapted a peripheral oximetry probe with a metal strip and placed it across the patient's cheek and noted improved reliability of these "buccal" measurements compared with peripheral ones....
متن کاملFull Thickness Burn on the Finger due to Pulse Oximetry during Magnetic Resonance Imaging in a Conscious Patient
Magnetic resonance imaging (MRI) is a safe and accurate radiologic tool [1]. However, there is also a risk of physical injury or thermal injury [1,2]. During MRI scanning, wearing monitoring equipment containing metal such as pulse oximetry and ECG monitoring leads can cause contact burns; a few cases of thermal injury during MRI scanning in unconscious patients have been reported [1,2]. Howeve...
متن کاملValidity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome
Introduction: One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio. Methods and Materials: In a cross sectional study we enrolled 105 sample o...
متن کاملCan we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?
Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 39 5 Pt 1 شماره
صفحات -
تاریخ انتشار 1992