A Versatile Multichannel Electrical Stimulator for

نویسندگان

  • Ying-Han Chiou
  • Han-Chang Wu
  • Shih-Ching Chen
  • Te-Son Kuo
چکیده

Functional electrical stimulation has been applied to restore the muscle activity of paralyzed patients who suffer from spinal cord injuries and related neural impairments for several decades. In this paper, a direct-synthesized arbitrary waveform stimulator for multichannel FES applications is described. A novel element-envelope method is proposed. A digital signal processor is chosen to synthesize required stimulating patterns with high time-resolution, and it preserves the ability to adjust stimulation parameters dynamically. Also, the system can provide bi-phasic, voltage-controlled constant-current patterns while remaining high-voltage compliance and wide bandwidth. The proposed stimulator can be considered as a full-featured stimulator for various FES applications with its flexibility in pattern generation and feedback processing capabilities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A versatile multichannel direct-synthesized electrical stimulator for FES applications

Functional electrical stimulation (FES) has been applied to restore or maintain the muscle activity of paralyzed patients who suffer from spinal cord injuries and related neural impairments for several decades. In this paper, a direct-synthesized arbitrary waveform stimulator for multichannel FES applications is described. A novel element-envelope method is proposed for flexible waveform genera...

متن کامل

An implantable mixed analog/digital neural stimulator circuit

This paper describes a chip for a multichannel neural stimulator for functional electrical stimulation. The chip performs all the signal processing required in an implanted neural stimulator. The power and signal transmission to the stimulator is carried out via an induce -

متن کامل

The Implementation of DSP-Based Controller for a Multichannel Programmable Electrical Stimulation System and Its User-Friendly Man-Machine Interface Design

Electrical stimulators have been applied in many fields for many decades, especially in restoring the muscle activities of paralyzed patients who suffer from spinal cord injuries or related neural impairments. In this paper, a DSP-based multichannel programmable electrical stimulation system is proposed. The “element-envelope” method is also used for flexible and arbitrary waveform generation a...

متن کامل

Design of Monophasic Spike-Exponential Waveform for Functional Electrical Stimulator Based on Pulse Width Modulation

The Functional Electrical Stimulator design using monophasic spike-exponential waveform was proposed and described in this study. The monophasic square waveform has benefit in generating an action potential, but it could cause side effects such as toxic caused by the electrode polarization. The square waveform signal which the frequency and pulse width could be modulated was manipulated to be t...

متن کامل

The design of an embedded spinal cord stimulator

Spinal cord stimulation is a physical therapy methodology utilizing electrical impulses, pulses, or a combination of various standard electrical waveforms to block pain. However, standard forms are not functioning effectively for each illness due to the unique conditions of the patient. Therefore, patient-specific waveforms (or user-defined waveforms) integrated with nondestructive, complete, o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001