BACKGROUND Microvolt T-wave alternans (MTWA) is a recommended noninvasive diagnostic test for predicting the risk of sudden cardiac death (SCD). However, about 6% to 41% of MTWA results are indeterminate. The causes, interpretation and clinical significance of these results have not been not clearly established. AIM To assess frequency, causes, and prognostic significance of indeterminate MTWA results in a group of patients with left ventricular dysfunction referred for implantable cardioverter-defibrillator (ICD) placement in the primary prevention of SCD. METHODS Patients with left ventricular ejection fraction (LVEF) ≤ 35% underwent MTWA evaluation during a treadmill exercise test (CH2000 system, Cambridge Heart Inc. Bedford MA, USA). MTWA results (spectral analysis) were categorised as positive, negative, or indeterminate (MTWApos, MTWAneg, and MTWAnd, respectively). Patients were followed up for the occurrence of SCD, ventricular tachycardia (VT), and ventricular fibrillation (VF). RESULTS Mean age of participants (n = 93) was 63 ± 13 years, an ischaemic cause of left ventricular dysfunction was present in 70 (75%) patients, and average LVEF was 30 ± 7%. MTWApos was found in 27 (29%) patients, MTWAneg in 41 (44%) patients, and MTWAnd in 25 (27%) patients. Causes of MTWAnd included inability to achieve a diagnostic HR in 12 (48%) patients, ventricular ectopy in 5 (20%) patients, nonsustained alternans in 3 (12%) patients, and technical factors (artifacts due to a high noise level) in 5 patients (20% of indeterminate results, 5.4% of the whole study group). During follow-up, 8 SCD/VT/VF events were noted (4 patients with MTWApos and 4 patients with MTWAnd due to patient-related factors). The rate of SCD/VT/VF was 35% in patients with MTWApos and 34.6% in MTWAnd due to patients-related factors, significantly higher compared to those with MTWAneg or MTWAnd due to technical factors (p 〈 0.05). CONCLUSIONS Although the proportion of indeterminate MTWA results in patients with left ventricular dysfunction referred for ICD implantation in the primary prevention of SCD was high, the proportion of indeterminate MTWA results due to technical factors, probably of no prognostic significance, was small.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of microvolt T-wave alternans in assessment of arrhythmia vulnerability among patients with heart failure and systolic dysfunction: primary results from the T-wave alternans sudden cardiac death in heart failure trial substudy.

BACKGROUND Sudden cardiac death remains a leading cause of mortality despite advances in medical treatment for the prevention of ischemic heart disease and heart failure. Recent studies showed a benefit of implantable cardioverter defibrillator implantation, but appropriate shocks for ventricular tachyarrhythmias were noted only in a minority of patients during 4 to 5 years of follow-up. Accord...

متن کامل

Application of microvolt T-wave alternans testing in scheduling implantable cardioverter-defibrillator placement for the primary prevention of sudden cardiac death in patients with left ventricular dysfunction.

BACKGROUND Patients with left ventricular ejection fraction (LVEF) ≤ 35% are eligible for implantable cardioverter-defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD). This recommendation results in continuously growing waiting lists of patients who have been qualified for and are awaiting the procedure. Whiled reduced LVEF is a feature shared by all the patie...

متن کامل

Multiple autonomic and repolarization investigation of sudden cardiac death in dilated cardiomyopathy and controls.

BACKGROUND Prophylactic defibrillator implantation is recommended in dilated, nonischemic heart disease and left ventricular ejection fraction of ≤0.30 to 0.35. Noninvasive testing should improve accuracy in decision making of prophylactic defibrillator implantation. METHODS AND RESULTS We enrolled 60 patients (median age, 57 years) with dilated cardiomyopathy and left ventricular ejection fr...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Risk stratification and prevention of sudden death in patients with heart failure.

OPINION STATEMENT For almost the past decade, recommendations for the use of implantable cardioverter defibrillators (ICDs) for primary prevention of sudden cardiac death have been based upon the left ventricular ejection fraction (LVEF). Current guidelines recommend an ICD for heart failure patients with LVEF ≤35% and NYHA functional class of II or III; however, because the majority of heart f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 70 8  شماره 

صفحات  -

تاریخ انتشار 2012