Impact of the Temperature Dependency of Fiberglass Insulation R-Value on Cooling Energy Use in Buildings

نویسندگان

  • Ronnen Levinson
  • Hashem Akbari
  • Lisa M. Gartland
  • Ernest Orlando
چکیده

Building energy models usually employ a constant, room-temperature-measured value for the thermal resistance of fiberglass roof insulation. In summer, however, the mean temperature of roof insulation can rise significantly above room temperature, lowering the insulation’s thermal resistance by 10% to 20%. Though the temperature dependence of the thermal resistance of porous materials like fiberglass has been extensively studied, it is difficult to theoretically predict the variation with temperature of a particular fiberglass blanket, from first principles. Heat transfer within fiberglass is complicated by the presence of three significant mechanisms—conduction through air, conduction through the glass matrix, and radiative exchange within the matrix—and a complex, unknown internal geometry. Purely theoretical models of fiberglass heat transfer assume highly simplified matrix structures and require typically-unavailable information about the fiberglass, such as its optical properties. There is also a dearth of useful experimental data. While the thermal resistances of many individual fiberglass samples have been measured, there is only one practical published table of thermal resistance vs. both temperature and density. Data from this table was incorporated in the DOE-2 building energy model. DOE-2 was used to simulate the roof surface temperature, roof heat flux, and cooling energy consumption of a school bungalow whose temperature and energy use had been monitored in 1992. The DOE-2 predictions made with and without temperature variation of thermal conductivity were compared to measured values. Simulations were also run for a typical office building. Annual cooling energy loads and annual peak hourly cooling powers were calculated for the office building using both fixed and variable thermal conductivities, and using five different climates. The decrease in the R-value of the office building’s roof led to a 2% to 4% increase in annual cooling energy load.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Optimum Insulation Thickness for Building Walls in Iran Using Life Cycle Cost Analysis

Air-Conditioning (AC) systems are responsible for a considerable portion of the energy consumption in buildings located in high cooling load requiring regions of Iran. In addition, the heat flow through the buildingschr('39') external walls plays a major role in cooling load estimations for the countrychr('39')s hot regions. Therefore, application of insulation materials in external walls has g...

متن کامل

Comparative study between dynamic transient and degree-hours methods to estimate heating and cooling loads of building’s wall

In this paper, dynamic transient method and conventional degree-hours method (static) have been compared to estimate heating and cooling loads of building’s wall. All main wall surfaces of various orientations, i.e.South, West, East, North, and horizontal are considered in the climate of Tehran, Iran. In this study, a conventional wall structure, which is comprisedconcrete as main wall material...

متن کامل

Regional climate changes and their effects on monthly energy consumption in buildings in Iran

This present research work was carried out to evaluate the energy consumption in a typical Iranian building based on the forecast of climatic variables. Thus, the LARS-WG model was validated for some northwest stations of Iran, including Tabriz, Ardebil, Oromieh, Kermanshah, Hamedan, Sannandaj, Qazvin, and Zanjan. The average monthly outdoor temperature was forecasted from 2011 to 2100. The rel...

متن کامل

Effect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems

The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...

متن کامل

Potentials of Vernacular Climatic Solutions (VCS) in Energy Efficiency of Domestic Buildings in Hot and Humid Climate: The Case Study of Bushehr, Iran

This study aims to use vernacular climatic solutions (VCS) of traditional dwellings of Bushehr in common residential buildings of this city in southern Iran and answer to the question that “What is the effect of VCS in terms of energy consumption in these buildings?”. This research was conducted on two levels. At the first level, after selecting an existing model of common residential buildings...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996