Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction.

نویسندگان

  • Arman Rahmim
  • Yun Zhou
  • Jing Tang
  • Lijun Lu
  • Vesna Sossi
  • Dean F Wong
چکیده

Due to high noise levels in the voxel kinetics, development of reliable parametric imaging algorithms remains one of most active areas in dynamic brain PET imaging, which in the vast majority of cases involves receptor/transporter studies with reversibly binding tracers. As such, the focus of this work has been to develop a novel direct 4D parametric image reconstruction scheme for such tracers. Based on a relative equilibrium (RE) graphical analysis formulation (Zhou et al 2009b Neuroimage 44 661-70), we developed a closed-form 4D EM algorithm to directly reconstruct distribution volume (DV) parametric images within a plasma input model, as well as DV ratio (DVR) images within a reference tissue model scheme (wherein an initial reconstruction was used to estimate the reference tissue time-activity curves). A particular challenge with the direct 4D EM formulation is that the intercept parameters in graphical (linearized) analysis of reversible tracers (e.g. Logan or RE analysis) are commonly negative (unlike for irreversible tracers, e.g. using Patlak analysis). Subsequently, we focused our attention on the AB-EM algorithm, derived by Byrne (1998, Inverse Problems 14 1455-67) to allow inclusion of prior information about the lower (A) and upper (B) bounds for image values. We then generalized this algorithm to the 4D EM framework, thus allowing negative intercept parameters. Furthermore, our 4D AB-EM algorithm incorporated and emphasized the use of spatially varying lower bounds to achieve enhanced performance. As validation, the means of parameters estimated from 55 human (11)C-raclopride dynamic PET studies were used for extensive simulations using a mathematical brain phantom. Images were reconstructed using conventional indirect as well as proposed direct parametric imaging methods. Noise versus bias quantitative measurements were performed in various regions of the brain. Direct 4D EM reconstruction resulted in notable qualitative and quantitative accuracy improvements (over 35% noise reduction, with matched bias, in both plasma and reference-tissue input models). Similar improvements were also observed in the coefficient of variation of the estimated DV and DVR values even for relatively low uptake cortical regions, suggesting the enhanced ability for robust parameter estimation. The method was also tested on a 90 min (11)C-raclopride patient study performed on the high-resolution research tomograph wherein the proposed method was shown across a variety of regions to outperform the conventional method in the sense that for a given DVR value, improved noise levels were observed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole-body PET parametric imaging employing direct 4D nested reconstruction and a generalized non-linear Patlak model

Graphical analysis is employed in the research setting to provide quantitative estimation of PET tracer kinetics from dynamic images at a single bed. Recently, we proposed a multi-bed dynamic acquisition framework enabling clinically feasible whole-body parametric PET imaging by employing post-reconstruction parameter estimation. In addition, by incorporating linear Patlak modeling within the s...

متن کامل

Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction.

Whole-body (WB) dynamic PET has recently demonstrated its potential in translating the quantitative benefits of parametric imaging to the clinic. Post-reconstruction standard Patlak (sPatlak) WB graphical analysis utilizes multi-bed multi-pass PET acquisition to produce quantitative WB images of the tracer influx rate K i as a complimentary metric to the semi-quantitative standardized uptake va...

متن کامل

4D PET: Beyond conventional dynamic PET imaging

  In this paper, we review novel techniques in the emerging field of spatiotemporal 4D PET imaging. We will discuss existing limitations in conventional dynamic PET imaging which involves independent reconstruction of dynamic PET datasets. Various approaches that seek to attempt some or all of these limitations are reviewed in this work, including techniques that util...

متن کامل

Direct Parametric Reconstruction for Dynamic [18F]FDG PET/CT Imaging in the Body

Abdominal and thoracic [F]FDG PET/CT imaging is routinely used in clinical practice and drug development but parametric imaging based on full kinetic analysis is rarely used due to noise induced bias and variance in kinetic parameters and analysis is usually restricted to semi-quantitative indices. Direct parametric estimation using 4D image reconstruction can potentially provide parametric map...

متن کامل

Direct 4D Parametric Imaging in Dynamic Myocardial Perfusion PET

yocardial perfusion (MP) PET provides improved diagnostic quality, certainty, and accuracy over conventional MP SPECT imaging [1-5]. The prognos-tic value in predicting adverse cardiac outcomes has also been demonstrated in an increasing number of studies [6-8]. In particular, dynamic MP PET imaging followed by tracer kinetic analysis (e.g. compartmental modelling applied to Rb-82 [9-15]), prov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2012