Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry

نویسندگان

  • Marcin Masalski
  • Tomasz Grysiński
  • Tomasz Kręcicki
چکیده

BACKGROUND Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. OBJECTIVE This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. METHODS Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. RESULTS A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. CONCLUSIONS The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis

BACKGROUND Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. OBJECTIVE The aim of this research was to determine the measurement error of the hearing threshold determined in the way described above and to identify and analyze factors in...

متن کامل

An iOS-based speech audiometry for self-assessment of hearing status

Speech audiometry is one of the methods for evaluating hearing status, and recently it’s tended to be implemented on mobile phones with the development of internet and smart devices. Although several applications include the function of speech audiometry, the effectiveness of this function was rarely reported. In this work, we developed an Apple iOS-based application (Hearing Assistant) with fu...

متن کامل

Pure Tone Audiometer

Estimation of pure tone hearing threshold is a part of hearing tests conducted in order to know the sensitivity of the human auditory system. This paper presents manual audiometer implemented in Matlab which can be used to conduct such measurements. Audiometer was calibrated by means of an artificial ear and pistonphone. Modified Hughson-Westlake method [1] usually used in manual audiometry is ...

متن کامل

Theory and practice of pure tone audiometry

Pure tone audiometry indicates what hearing thresholds (dB) are required to just be able to perceive a tone at different frequencies (Hz). A pure tone audiology threshold at a specific frequency is the decibel level at which a sound is perceived 50% of the time. The decibel scale used in pure tone audiometry is dB Hearing Level (dB HL). The dB HL intensity scale is based on normal human hearing...

متن کامل

Pure Tone Audiometry

Pure tone audiometry is the standard behavioral assessment of an individual’s hearing. The results of pure tone audiometry are recorded on a chart or form called an audiogram. In most cases a pure tone audiogram is easy to obtain and provides information about peripheral hearing acuity across the frequencies used in speech. It allows for a quick view of how well, or how poorly, an individual ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2018