Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial.

نویسندگان

  • Elvin Kedhi
  • Kaiyum Sheik Joesoef
  • Eugene McFadden
  • Jochem Wassing
  • Carlos van Mieghem
  • Dick Goedhart
  • Pieter Cornelis Smits
چکیده

BACKGROUND Everolimus-eluting and paclitaxel-eluting stents, compared with bare metal stents, reduced the risk of restenosis in clinical trials with strict inclusion and exclusion criteria. We compared the safety and efficacy of the second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice. METHODS We randomly assigned 1800 consecutive patients (aged 18-85 years) undergoing percutaneous coronary intervention at one centre to treatment with everolimus-eluting or paclitaxel-eluting stents. The primary endpoint was a composite of safety and efficacy (all-cause mortality, myocardial infarction, and target vessel revascularisation) within 12 months. Patients were not told which stent they had been allocated. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01016041. FINDINGS Follow-up was completed in 1797 patients. The primary endpoint occurred in 56 (6%) of 897 patients in the everolimus-eluting stent group versus 82 (9%) of 903 in the paclitaxel-eluting stent group (relative risk 0.69 [95% CI 0.50-0.95], p value for superiority=0.02). The difference was attributable to a lower rate of stent thrombosis (6 [<1%] vs 23 [3%], 0.26 [0.11-0-64], p=0.002), myocardial infarction (25 [3%] vs 48 [5%], 0.52 [0.33-0.84], p=0.007), and target vessel revascularisation (21 [2%] vs 54 [6%], 0.39 [0.24-0.64], p=0.0001). Cardiac death, non-fatal myocardial infarction, or target lesion revascularisation occurred in 44 [5%] patients in the everolimus-eluting stent group versus 74 [8%] patients in the paclitaxel-eluting stent group, p value for superiority was 0.005. INTERPRETATION The everolimus-eluting stent is better than the second generation paclitaxel-eluting stent in unselected patients in terms of safety and efficacy. On the basis of our results, we suggest that paclitaxel-eluting stents should no longer be used in everyday clinical practice. FUNDING Unrestricted grants from Abbott Vascular and Boston Scientific.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials.

OBJECTIVES The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES). BACKGROUND Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention. METHODS Patient-level data were pooled from t...

متن کامل

Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher((R))) and paclitaxel-eluting (Taxus((R))) stents and later approved second-generation everolimus-eluting (Xience V((R)...

متن کامل

Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial

BACKGROUND Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The ...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lancet

دوره 375 9710  شماره 

صفحات  -

تاریخ انتشار 2010