Use of an impedance threshold device improves short-term outcomes following out-of-hospital cardiac arrest.

نویسندگان

  • Roger C Thayne
  • D Colin Thomas
  • James D Neville
  • Anton Van Dellen
چکیده

INTRODUCTION An impedance threshold device (ITD) has been developed for the treatment of cardiac arrest to augment circulation to the heart and brain during cardiopulmonary resuscitation (CPR). The ITD has ventilation timing lights that flash at 12 min(-1) to discourage excessive ventilation rates. HYPOTHESIS Implementation of the ITD during conventional manual CPR in a large emergency medical services (EMS) system (Staffordshire, UK) is safe, feasible and will improve short-term survival. METHODS ITD use was implemented by the Staffordshire Ambulance Trust, which treats 1600 cardiac arrests per year with 90 advanced life support (ALS) units and an average response time of 6.3 min. During training, rescuers learned to use the ventilation timing lights to discourage hyperventilation. Rescuers applied the device after tracheal intubation. They were trained to allow the chest to recoil fully after each compression. Prospective ITD use in adults receiving conventional manual CPR for non-traumatic cardiac arrest was compared to matched historical controls receiving conventional manual CPR without inspiratory impedance. All received similar ALS care. The primary endpoint was admission to the emergency department (ED) alive following cardiac arrest. Chi-square, Fisher's exact and Kolmogorov-Smirnov tests were used for statistical analyses. RESULTS Survival (alive upon ED admission) in all patients receiving an ITD (61/181 [34%]) improved by 50% compared to historical controls (180/808 [22%]) (P<0.01). Survival in patients presenting in asystole tripled in the group receiving an ITD (26/76 [34%]) compared with historical controls (39/351 [11%]) (P=0.001). There were no significant adverse events. CONCLUSIONS The ITD was used safely and effectively in a large, diverse EMS system and markedly improved short-term survival for adult patients in non-traumatic cardiac arrest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest.

OBJECTIVE To determine whether an impedance threshold device, designed to enhance circulation, would increase acute resuscitation rates for patients in cardiac arrest receiving conventional manual cardiopulmonary resuscitation. DESIGN Prospective, randomized, double-blind, intention-to-treat. SETTING Out-of-hospital trial conducted in the Milwaukee, WI, emergency medical services system. ...

متن کامل

Impact of impedance threshold devices on cardiopulmonary resuscitation: a systematic review and meta-analysis of randomized controlled studies.

OBJECTIVES Vital organ hypoperfusion significantly contributes to the dismal survival rates observed with manual cardiopulmonary resuscitation after cardiac arrest. The impedance threshold device is a valve which reduces air entry into lungs during chest recoil between chest compressions, producing a potentially beneficial decrease in intrathoracic pressure and thus increasing venous return to ...

متن کامل

Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest.

BACKGROUND Active compression-decompression (ACD) CPR combined with an inspiratory impedance threshold device (ITD) improves vital organ blood flow during cardiac arrest. This study compared survival rates with ACD+ITD CPR versus standard manual CPR (S-CPR). METHODS AND RESULTS A prospective, controlled trial was performed in Mainz, Germany, in which a 2-tiered emergency response included ear...

متن کامل

Clinical Investigations Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest*

An inspiratory impedance threshold device (ITD) has recently been demonstrated to enhance vital organ perfusion and neurologically intact survival rates in animals in cardiac arrest during standard cardiopulmonary resuscitation (CPR) (1– 4). The ITD is a small, 35-mL device that can attach to a variety of airway adjuncts, including a facemask and endotracheal tube (Fig. 1). By selectively imped...

متن کامل

Factors Associated with Survival Rate after Cardiopulmonary Resuscitation

Introduction: Cardiovascular disease is considered as the most important cause of mortality among men and women throughout the world. This condition causes sudden cardiac arrest in more than half of the cases. To reduce mortality due to this disease, cardiopulmonary resuscitation (CPR) and the determinants of its success are the focus of researchers. Objective: The aim of this study was to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Resuscitation

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 2005