High resolution direct measurement of temperature distribution in silicon nanophotonics devices.
نویسندگان
چکیده
Following the miniaturization of photonic devices and the increase in data rates, the issues of self heating and heat removal in active nanophotonic devices should be considered and studied in more details. In this paper we use the approach of Scanning Thermal Microscopy (SThM) to obtain an image of the temperature field of a silicon micro ring resonator with sub-micron spatial resolution. The temperature rise in the device is a result of self heating which is caused by free carrier absorption in the doped silicon. The temperature is measured locally and directly using a temperature sensitive AFM probe. We show that this local temperature measurement is feasible in the photonic device despite the perturbation that is introduced by the probe. Using the above method we observed a significant self heating of about 10 degrees within the device.
منابع مشابه
Direct imaging of nanogap-mode plasmon-resonant fields.
We perform direct local-field imaging of a plasmon-resonant gold nanoparticle pair separated by a gap of several nanometers using a scattering-type near-field optical microscope with a sharp silicon tip of atomic force microscope. The sharp tip allows the access for the nanogap and the high spatial resolution. Our results provide experimental evidence that the nanogap structure produces an opti...
متن کاملA New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System
Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...
متن کاملSilicon Nanophotonics for On-Chip High-Speed Parametric Optical Processing
Utilizing all-optical parametric processing in a silicon photonic chip, we demonstrate wavelength conversion for 10 and 40-Gb/s NRZ as well as 160-Gb/s pulsed-RZ data signals, and demonstrate eight-way wavelength multicasting at 40-Gb/s NRZ data rates. ©2009 Optical Society of America OCIS codes: (130.7405) Wavelength conversion devices; (190.4380) Nonlinear optics, four-wave mixing
متن کاملA quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملMulti-objective Measurement Devices Allocation Using State Estimation in Distribution System
Allocation of measurement devices is a necessity of distribution system which is an application of state estimation. In this paper, the problem of active and reactive measurement devices is modeling using a multi-objective method. The objectives of the problem are to minimize the use of measurement devices, increase in state estimation output, improve the state estimation quality and reduce cos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 21 24 شماره
صفحات -
تاریخ انتشار 2013