Evaluation of the position and function of aqueous drainage implants with magnetic resonance imaging.
نویسندگان
چکیده
PURPOSE To evaluate position and function of antiglaucomatous Ahmed and Molteno shunts using magnetic resonance imaging with head and surface coils. METHODS Eight patients (5 males) with shunt implants were included, 4 with Ahmed (FP-7) and 4 with Molteno (s1, single plated). All patients were operated at least 6 months before imaging. In 3 cases (2 with Molteno and 1 with Ahmed shunt), the intraocular pressure (IOP) was above 21 mm Hg, despite maximal medical treatment. The shunt endplate, tube and filtering blebs were identified in T1-weighted and T2-weighted images with both head and surface coils. Volumetric measurements of the orbits, eyeball, and filtering bleb and calculation of the endplate position along sagittal, transverse, and vertical axes were performed in T1-weighted and T2-weighted images using head coils. RESULTS The shunt endplate was identified in T1-weighted and T2-weighted images (head coils) as a low intensity (dark) circumlinear band at the superotemporal aspect of the eyeball, surrounded by a pocket of water density, corresponding to the filtering bleb. The anterior position of the endplate, and smaller volume of the orbital cavity (less available orbital space) were associated with higher IOP. Filtering bleb volume was inversely correlated with IOP. In the unsuccessful cases, filtering bleb was absent. CONCLUSIONS Magnetic resonance imaging provides insights into the mechanism of aqueous outflow and causes of failure of shunts. A lower orbital volume is associated with anterior position of the shunt endplate and poor shunt performance.
منابع مشابه
Correlation between condyle morphology and disk position of disc displacement in patients with TMJ internal derangements by magnetic resonance imaging
Background and Aims :The most frequent cause of TMJ dysfunction is internal derangement which that largely involves the function of the articular disc. Anterior disc displacement (ADD) is one of the major findings in TMJ internal derangement. Since the importance of knowledge of its etiology and also The role of all structural indicators association with TMD was not evaluated, in this researc...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملUsing functional magnetic resonance imaging (fMRI) to explore brain function: cortical representations of language critical areas
Pre-operative determination of the dominant hemisphere for speech and speech associated sensory and motor regions has been of great interest for the neurological surgeons. This dilemma has been of at most importance, but difficult to achieve, requiring either invasive (Wada test) or non-invasive methods (Brain Mapping). In the present study we have employed functional Magnetic Resonance Imaging...
متن کاملCLINICAL CORRELATIONS BETWEEN AUDITORY BRAIN STEM RESPONSE AND MAGNETIC RESONANCE IMAGING IN PATIENTS WITH DEFINITE MULTIPLE SCLEROSIS
In an attempt to assess objectively the integrity of the auditory pathways in 30 patients with definite multiple sclerosis (MS), an audiometric evaluation was performed and auditory brainstem responses (ABRs) were obtained. Stressing the auditory system by increasing the stimulation rate showed some enhancement in the identification of MS. 24 (RO%) patients had an abnormal ABR along with c...
متن کاملSegmentation of Magnetic Resonance Brain Imaging Based on Graph Theory
Introduction: Segmentation of brain images especially from magnetic resonance imaging (MRI) is an essential requirement in medical imaging since the tissues, edges, and boundaries between them are ambiguous and difficult to detect, due to the proximity of the brightness levels of the images. Material and Methods: In this paper, the graph-base...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of glaucoma
دوره 18 6 شماره
صفحات -
تاریخ انتشار 2009