Perfusion-sensitive MR imaging of gliomas: comparison between gradient-echo and spin-echo echo-planar imaging techniques.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The different sensitivities to vessel size of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI) might indicate the relative cerebral blood volumes (rCBVs) of different tumor sizes. The techniques of GE-EPI and SE-EPI were compared for detecting low- versus high-grade gliomas. METHODS Six patients with low-grade gliomas and 19 patients with high-grade gliomas underwent two perfusion-sensitive MR procedures, one produced by a GE- and the other by an SE-EPI technique. Maximum rCBV ratios normalized with rCBV of contralateral white matter were calculated for evaluation. P <.05 was considered statistically significant. RESULTS Maximum rCBV ratios of high-grade gliomas obtained with the GE-EPI technique (mean, 5.0 +/- 2.9) were significantly higher than those obtained with the SE-EPI technique (mean, 2.9 +/- 2.3) (P =.02). Maximum rCBV ratios of low-grade gliomas obtained with the GE-EPI technique (mean, 1.2 +/- 0.7) were almost equal to those obtained with the SE-EPI technique (mean, 1.2 +/- 0.6), and there was no significant difference (P =.66). The difference in the maximum rCBV ratios between the low- and high-grade gliomas reached significance when obtained with the GE-EPI technique (P =.01). CONCLUSION The GE-EPI technique seems more useful for detecting low- versus high-grade gliomas than the SE-EPI technique.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملQuantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging.
PURPOSE To implement an arterial spin labeling technique that is feasible in routine examinations and to test the method and compare it with dynamic susceptibility-weighted contrast material-enhanced magnetic resonance (MR) imaging for evaluation of tumor blood flow (TBF) in patients with brain tumors. MATERIALS AND METHODS Thirty-six patients with histologically proven brain tumors were exam...
متن کاملIron-induced susceptibility effect at the globus pallidus causes underestimation of flow and volume on dynamic susceptibility contrast-enhanced MR perfusion images.
BACKGROUND AND PURPOSE Age-related iron accumulation in extrapyramidal nuclei causes T2 shortening, which may result in decreased signal intensity in these areas on MR images. Because the dynamic susceptibility contrast-enhanced technique uses heavily T2*- or T2-weighted images, the iron-induced susceptibility may have direct impact on perfusion imaging. The purpose of this study was to assess ...
متن کاملReduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.
Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of ...
متن کاملGRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.
A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 22 7 شماره
صفحات -
تاریخ انتشار 2001