InBody S10 Application
ثبت نشده
چکیده
To determine the most potent bioelectrical impedance analysis(BIA) marker of malnutrition and to adjust its application to hemodialysis(HD) patients, t h i s s t u d y measured the fol lowing: ICW , ECW , TBW , FFMI (FFM/height2), reactance, resistance and PA by utilizing InBody S10 in 99 maintenance HD patients in Lithuania, whose mean age was 58.7±14.38y, the nutritional status was examined using SGA (Subjective Global Assessment), serum albumin and BMI. According to SGA assessment, 57.6% of the patients were in well nourished, 28.3% were in moderatly malnourished status and 14.1% were in severely malnourished, and mean PA was 4.88±1.08 ̊ in all subjects. According to the multivariate logistic regression analysis result, the PA was the most potent predictor of the SGA-defined malnutrition (OR = 3.69, p <0.002) (Table 2). According to the PA value, less than 5th percentile was 27.3%, lower than 50th percentile was 85.9%; and moderately malnourished group belonged to <25th percentile (AUC=0.7, p<0.01), severe malnutrition status group belonged to <15th percentile (AUC=0.74, p<0.005). The PA measured by the BIA is the most accurate and appropriate method of nutritional evaluation . Furthermore, despite excess fluid, age and gender being important limitations in the application of BIA, PA can be adjusted for these factors and used accordingly.
منابع مشابه
Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis
Adequate fluid management is an important therapeutic goal of dialysis. Recently, bioelectrical impedance methods have been used to determine body fluid status, but pediatric reports are rare. To determine the accuracy of bioelectrical impedance methods in the assessment of body fluid statusof children undergoing hemodialysis (HD), 12 children on HD were studied. A multi-frequency bioimpedance ...
متن کاملSmartphone-Based Bioelectrical Impedance Analysis Devices for Daily Obesity Management
Current bioelectric impedance analysis (BIA) systems are often large, cumbersome devices which require strict electrode placement on the user, thus inhibiting mobile capabilities. In this work, we developed a handheld BIA device that measures impedance from multiple frequencies (5 kHz~200 kHz) with four contact electrodes and evaluated the BIA device against standard body composition analysis s...
متن کاملConcordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study
BACKGROUND Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of ...
متن کاملEffects of proprioceptive neuromuscular facilitation stretching and deep-breathing exercises on upper extremity lymphedema in stroke patients
[Purpose] The purpose of this study was to determine the effects of deep-breathing and proprioceptive neuromuscular facilitation stretching exercises on upper limb lymphedema in stroke patients. [Subjects and Methods] The study consisted of 10 patients with lymphedema that had occurred after stroke. Neurodevelopmental treatment was applied in the same manner as that used for the existing treatm...
متن کاملGFP variants with alternative β-strands and their application as light-driven protease sensors: a tale of two tails.
Green fluorescent protein (GFP) variants that carry one extra strand 10 (s10) were created and characterized, and their possible applications were explored. These proteins can fold with either one or the other s10, and the ratio of the two folded forms, unambiguously distinguished by their resulting colors, can be systematically modulated by mutating the residues on s10 or by changing the lengt...
متن کامل