A Coherent FM Laser Radar Based System for Remote Metrology in ITER*
نویسندگان
چکیده
The plasma facing surfaces in ITER must be aligned to millimeter accuracy with respect to the magnetic flux surfaces to prevent impurity influx into the plasma and to avoid component damage. Checking of in-vessel component alignment during initial assembly, operation, and subsequent maintenance is anticipated. A fully remote metrology system is necessary, particularly since major remote operations such as shield blanket exchange and divertor cassette replacement are planned. The metrology system must be compatible with the ITER in-vessel environment of high gamma radiation (-IO6 Whr), super-clean ultra-high-vacuum Torr), and elevated temperature (-200°C). A fast scanning rate is required since the plasma facing surface in ITER is very large (-1500 m2). A coherent FM laser radar based metrology system, developed by Coleman Research Corporation, is being adopted to accomplish this task. Conceptually, this metrology system consists of a compact (few cm3) remotely deployed laser transceiver optics module, linked through fiber optics to the laser source and imaging units that are located outside the biological shield. Range measurements conducted on a variety of surfaces using the system have yielded sub-millimeter accuracy. Therefore, the technique will easily meet the precision requirement for the ITER application. Computer simulations have been carried out to determine the optimum number of units required for complete mapping of the plasma facing surfaces. Most in-vessel components of the system appear to be radiation hardenable and vacuum compatible. Details of the system and developments required to make it fully compatible for ITER metrology application will be elaborated. and operation are anticipated. A controlled 3D metrology system, that can be remotely deployed to perform accurate mapping of the ITER in-vessel components and their support structures (i.e., vacuum vessel, blanketlshield, divertor, etc.) is required. Inspectionhiewing of plasma facing surfaces is also anticipated for troubleshooting during plasma operation.
منابع مشابه
Mathematically modeling of target speed effect on nonlinearity in DTLMI-based nano-metrology system
Jones matrix computation is one of the widely used methods in nonlinearitycalculation in laser interferometers. In this paper, the nonlinearity error in developedthree-longitudinal mode heterodyne interferometer (DTLMI) has been mathematicallymodeled at various speeds, by using Jones matrix calculations. This review has been donedespite the fact that simultaneously the main factors including no...
متن کاملAnalysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models
The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...
متن کاملPhase Correction for Coherent Noise Reduction in Short-Range Radar Measurements
Short-range scatterometer systems are used to obtain radar backscatter signatures for understanding the interaction between electromagnetic energy and geophysical media in a number of remote sensing applications. Unlike long-range and intermediate-range radar systems, the sensitivity of short-range radars is not limited by thermal noise, but rather by reflections and leakage signals from the an...
متن کاملControl of coherent light and its broad applications
A remarkable synergy has been formed between precision optical frequency metrology and ultrafast laser science. This has resulted in control of the frequency spectrum produced by mode-locked lasers, which consists of a regular “comb” of sharp lines. Such a controlled mode-locked laser is a “femtosecond optical frequency comb generator.” For a sufficiently broad comb, it is straightforward to de...
متن کاملCoherent Laser Radar Conference Off Line-of-Sight Measurements of Target Vibrational Features Using Laser Vibrometry
Laser vibrometry based on coherent detection techniques allows remote measuring of vibrational target characteristics with high resolution. Previous work concentrated on measurements where a direct line-of-sight between target and sensor was given. In this paper we investigate situations where the target is hidden and out-of-sight, but target-induced vibrations can be captured from the environm...
متن کامل