Heat stress while wearing long pants or shorts under firefighting protective clothing.
نویسندگان
چکیده
It was the purpose of this study to examine whether replacing long pants (P) with shorts (S) would reduce the heat stress of wearing firefighting protective clothing during exercise in a warm environment. Twenty-four Toronto Firefighters were allocated to one of four groups that performed heavy (H, 4.8 km x h(-1), 5% grade), moderate (M, 4.5 km x h(-1), 2.5% grade), light (L, 4.5 km x h(-1)) or very light (VL, 2.5 km x h(-1)) exercise while wearing their full protective ensemble and self-contained breathing apparatus. Participants performed a familiarization trial followed by two experimental trials at 35 degrees C and 50% relative humidity wearing either P or S under their protective overpants. Replacing P with S had no impact on the rectal temperature (Tre) or heart rate response during heavy or moderate exercise where exposure times were less than 1 h (40.8 +/- 5.8 and 53.5 +/- 9.2 min for H and M, respectively while wearing P, and 43.5 +/- 5.3 and 54.2 +/- 8.4 min, respectively while wearing S). In contrast, as exposure times were extended during lighter exercise Tre was reduced by as much as 0.4 degrees C after 80 min of exercise while wearing S. Exposure times were significantly increased from 65.8 +/- 9.6 and 83.5 +/- 11.6 min during L and VL, respectively while wearing P to 73.3 +/- 8.4 and 97.0 +/- 12.5 min, respectively while wearing S. It was concluded that replacing P with S under the firefighting protective clothing reduced the heat stress associated with wearing the protective ensemble and extended exposure times approximately 10 - 15% during light exercise. However, during heavier exercise where exposure times were less than 1 h replacing P with S was of little benefit.
منابع مشابه
The management of heat stress for the firefighter: a review of work conducted on behalf of the Toronto Fire Service.
This report provides a summary of research conducted through a grant provided by the Workplace Safety Insurance Board of Ontario. The research was divided into two phases; first, to define safe work limits for firefighters wearing their protective clothing and working in warm environments; and, the second, to examine strategies to reduce the thermal burden and extend the operational effectivene...
متن کاملActive versus passive cooling during work in warm environments while wearing firefighting protective clothing.
This study examined whether active or passive cooling during intermittent work reduced the heat strain associated with wearing firefighting protective clothing (FPC) and self-contained breathing apparatus (SCBA) in the heat (35 degrees Celsius, 50% relative humidity). Fifteen male Toronto firefighters participated in the heat-stress trials. Subjects walked at 4.5 km.h(-1) with 0% elevation on a...
متن کاملEffect of Protective Clothing and Fatigue on Functional Balance of Firefighters
Every year, more than 38,000 firefighters are injured on the fireground [1]. Among causes of moderate or severe injuries of firefighters, slips, trips, and falls are the most significant cause (28%) of firefighting injuries, followed by overexertion (23%), struck by objects (17%), exposure to detrimental environment (15%), and others (17%) [1]. A 2003 study reported that the average medical cos...
متن کاملEffect of base layer materials on physiological and perceptual responses to exercise in personal protective equipment.
Ten men (non-firefighters) completed a 110 min walking/recovery protocol (three 20-min exercise bouts, with recovery periods of 10, 20, and 20 min following successive bouts) in a thermoneutral laboratory while wearing firefighting personal protective equipment over one of four base layers: cotton, modacrylic, wool, and phase change material. There were no significant differences in changes in ...
متن کاملPerceptual and physiological heat strain: examination in firefighters in laboratory- and field-based studies.
Firefighting demands performing heavy muscular work under adverse and potentially dangerous conditions. Although the physiological and psychological responses to simulated firefighting activities have been described, the heat strain has not been characterised using standardised indices of exercise-heat strain. The purpose of the study is to describe the physiological and perceptual strain assoc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ergonomics
دوره 47 1 شماره
صفحات -
تاریخ انتشار 2004