A Miniature Aerosol Sensor for Detecting Polydisperse Airborne Ultrafine Particles

نویسندگان

  • Chao Zhang
  • Dingqu Wang
  • Rong Zhu
  • Wenming Yang
  • Peng Jiang
چکیده

Counting and sizing of polydisperse airborne nanoparticles have attracted most attentions owing to increasing widespread presence of airborne engineered nanoparticles or ultrafine particles. Here we report a miniature aerosol sensor to detect particle size distribution of polydisperse ultrafine particles based on ion diffusion charging and electrical detection. The aerosol sensor comprises a couple of planar electrodes printed on two circuit boards assembled in parallel, where charging, precipitation and measurement sections are integrated into one chip, which can detect aerosol particle size in of 30-500 nm, number concentration in range of 5 × 10²-10⁷ /cm³. The average relative errors of the measured aerosol number concentration and the particle size are estimated to be 12.2% and 13.5% respectively. A novel measurement scheme is proposed to actualize a real-time detection of polydisperse particles by successively modulating the measurement voltage and deducing the particle size distribution through a smart data fusion algorithm. The effectiveness of the aerosol sensor is experimentally demonstrated via measurements of polystyrene latex (PSL) aerosol and nucleic acid aerosol, as well as sodium chloride aerosol particles.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Micro Aerosol Sensor for the Measurement of Airborne Ultrafine Particles

Particle number concentration and particle size are the two key parameters used to characterize exposure to airborne nanoparticles or ultrafine particles that have attracted the most attention. This paper proposes a simple micro aerosol sensor for detecting the number concentration and particle size of ultrafine particles with diameters from 50 to 253 nm based on electrical diffusion charging. ...

متن کامل

Sampling methodologies and dosage assessment techniques for submicrometre and ultrafine virus aerosol particles.

AIMS The aerosolization and collection of submicrometre and ultrafine virus particles were studied with the objective of developing robust and accurate methodologies to study airborne viruses. METHODS AND RESULTS The collection efficiencies of three sampling devices used to sample airborne biological particles - the All Glass Impinger 30, the SKC BioSampler and a frit bubbler - were evaluated...

متن کامل

Particle Deposition in a Child Respiratory Tract Model: In Vivo Regional Deposition of Fine and Ultrafine Aerosols in Baboons

To relate exposure to adverse health effects, it is necessary to know where particles in the submicron range deposit in the respiratory tract. The possibly higher vulnerability of children requires specific inhalation studies. However, radio-aerosol deposition experiments involving children are rare because of ethical restrictions related to radiation exposure. Thus, an in vivo study was conduc...

متن کامل

Intercomparison of airborne and surfacebased measurements of condensation nuclei in the remote marine troposphere during ACE 1

Intercomparisons of aerosol particle number concentrations measured with various condensation particle counters (CPCs) during the first Aerosol Characterization Experiment (ACE 1) are made to assess the accuracy of the airborne measurements. When no ambient 3-10 nm diameter particles (nanoparticles) were present, median concentrations from four CPCs on the National Center for Atmospheric Resear...

متن کامل

Lung toxicity determination by in vitro exposure at the air liquid interface with an integrated online dose measurement

Epidemiological studies show an association between the concentration of ultrafine particles in the atmosphere and the rate of mortality or morbidity due to respiratory and cardiovascular diseases. For the quantitative assessment of the toxicity of airborne nanoparticles the dose–response relationship is tested in in vitro test systems using bioassays of cell cultures as sensor. For the air-liq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017