The effects of pad geometry and material properties on the biomechanical effectiveness of 26 commercially available hip protectors.

نویسندگان

  • Andrew C Laing
  • Fabio Feldman
  • Mona Jalili
  • Chun Ming Jimmy Tsai
  • Stephen N Robinovitch
چکیده

Wearable hip protectors (padded garments) represent a promising strategy to decrease impact force and hip fracture risk during falls, and a wide range of products are currently marketed. However, little is known about how design features of hip protectors influence biomechanical effectiveness. We used a mechanical test system (simulating sideways falls) to measure the attenuation in femoral neck force provided by 26 commercially available hip protectors at three impact velocities (2, 3, and 4m/s). We also used a materials testing machine to characterize the force-deflection properties of each device. Regression analyses were performed to determine which geometric (e.g., height, width, thickness, volume) and force-deflection properties were associated with force attenuation. At an impact velocity of 3m/s, the force attenuation provided by the various hip protectors ranged between 2.5% and 40%. Hip protectors with lower stiffness (measured at 500N) provided greater force attenuation at all velocities. Protectors that absorbed more energy demonstrated greater force attenuation at the higher impact velocities (3 and 4m/s conditions), while protectors that did not directly contact (but instead bridged) the skin overlying the greater trochanter attenuated more force at velocities of 2 and 3m/s. At these lower velocities, the force attenuation provided by protectors that contacted the skin overlying the greater trochanter increased with increasing pad width, thickness, and energy dissipation. By providing a comparison of the protective value of a large range of existing hip protectors, these results can help to guide consumers and researchers in selecting hip protectors, and in interpreting the results of previous clinical trials. Furthermore, by determining geometric and material parameters that influence biomechanical performance, our results should assist manufacturers in designing devices that offer improved performance and clinical effectiveness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of hip protectors for preventing hip fractures in elderly people: systematic review.

OBJECTIVES To present the updated results of systematic review of the current evidence for the effectiveness of hip protectors from reports of completed randomised trials, and to explore the evolution of that evidence. DESIGN Systematic review with meta-analysis. DATA SOURCES Cochrane Bone, Joint, and Muscle Trauma Group trials register (January 2005), Cochrane central register of controlle...

متن کامل

Investigation on the Deformation Behavior and Strain Distribution of Commercially Pure Aluminum after Circular Simple Shear Extrusion

Circular simple shear extrusion process was introduced as a new geometry for simple shear extrusion technique to fabricate ultrafine-grained materials. Similar to the simple shear extrusion method, this process is also based on direct extrusion, and the samples deform in a simple shear manner. In this investigation, the simulations were carried out using the commercial finite element code ABAQU...

متن کامل

Biomechanical comparison of hard and soft hip protectors, and the influence of soft tissue.

INTRODUCTION Hip protectors appear to be promising in preventing hip fractures. Currently, many different hip protectors exist, and it is not clear which hip protector has the best biomechanical properties. Therefore, the objective of this study was to compare the force attenuation capacity of 10 different hip protectors. Both hard hip protectors, which primarily shunt away energy, and soft hip...

متن کامل

Effects of Hip Geometry on Fracture Patterns of Proximal Femur

  Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF), intertrochanteric (ITF) and Subtrochanteric (ST...

متن کامل

A randomised trial of hip protector use by frail older women living in their own homes.

OBJECTIVES To investigate the efficacy and effectiveness of hip protectors in frail community living older women. DESIGN Randomised controlled trial. SETTING Aged care health services in New South Wales, Australia. PATIENTS 600 women 74 years of age or more (mean age 83 years), who had two or more falls or one fall requiring hospital admission in the previous year, and who lived in their ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 44 15  شماره 

صفحات  -

تاریخ انتشار 2011