Detection of intracochlear damage during cochlear implant electrode insertion using extracochlear measurements in the gerbil.
نویسندگان
چکیده
OBJECTIVES/HYPOTHESIS An intraoperative monitoring algorithm during cochlear implant electrode insertion could be used to detect trauma and guide electrode placement relative to surviving hair cells. The aim of this report was to assess the feasibility of using extracochlear recording sites to monitor acoustically evoked responses from surviving hair cells and neural elements during implantation in an animal model. STUDY DESIGN Animal experiments. METHODS The normal-hearing gerbil was used. Two recording methods, one using a lock-in amplifier and another using Fourier analysis of recorded signals, were used to obtain frequency-specific information about the responses to tones. Amplitude and threshold determinations were made at the round window and at three extracochlear sites. To induce intracochlear damage, a platinum-iridium wire was inserted through the round window. The wire was advanced, and changes in the potentials were correlated with cochlear contact. Anatomic integrity was assessed using cochlea whole mount preparations. RESULTS In general, the lock-in amplifier showed greater sensitivity and lower thresholds at higher frequencies relative to the Fourier method. Also, the lock-in amplifier was more resistant to masking effects. Both systems were able to detect loss of cochlear potentials secondary to intracochlear trauma. Histologic damage was seen in all cases and corresponded to electrophysiologic changes. CONCLUSIONS Impact of electrodes on cochlear structures affecting cochlear performance could be detected from several extracochlear sites. The lock-in amplifier demonstrated greater sensitivity and resistance to noise when compared to the fast Fourier transform recording paradigm. The latter showed greater flexibility of detecting and separating hair cell and neural potentials.
منابع مشابه
Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological chan...
متن کاملExtra- and Intracochlear Electrocochleography in Cochlear Implant Recipients.
OBJECTIVE To monitor cochlear function by extra- and intra-cochlear electrocochleography (ECoG) during and after cochlear implantation and thereby to enhance the understanding of changes in cochlear function following cochlear implantation surgery. METHODS ECoG responses to acoustic stimuli of 250, 500 and 1,000 Hz were recorded in 9 cochlear implant recipients with presurgical residual heari...
متن کاملImplantation of the Melbourne/Cochlear multiple-electrode extracochlear prosthesis.
The Melbourne/Cochlear multiple-electrode extracochlear implant is designed for deaf patients who are unsuited to multiple-electrode intracochlear implantation. The implant consists of a receiver-stimulator package connected via a lead wire assembly to six individual stimulating electrodes. There is a choice of two alternative surgical procedures, both of which are via a combined middle ear app...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملEvaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window
HYPOTHESIS This study aimed to evaluate whether there is a difference in the degree of intracochlear trauma when the cochlear implant electrode arrays is inserted through different quadrants of the round window membrane. BACKGROUND The benefits of residual hearing preservation in cochlear implant recipients have promoted the development of atraumatic surgeries. Minimal trauma during electrode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Laryngoscope
دوره 122 3 شماره
صفحات -
تاریخ انتشار 2012