Seismic Retrofit of Bridge Steel Truss Pier Anchorage Connections (2002-2003)
نویسنده
چکیده
In assessments of the seismic adequacy of existing steel bridges, the anchorage of steel truss piers to their foundations often has insufficient strength to resist seismic demands. Many other non-ductile failure locations may also exist along the seismic load path that cannot provide adequate seismic performance. Although strengthening is an option, this approach may only transfer damage to another location. An alternative solution could be to release the anchorage connection, allowing development of a rocking bridge pier system. The retrofit solution proposed here allows this rocking mechanism to develop, but complements it by adding passive energy dissipation devices across the anchorage interface to control the rocking response. Specially detailed, hysteretic energy dissipating elements (unbonded braces) act as ductile structural “fuses” in this application. An inherent re-centering capability is also possible. This research investigates the dynamic characteristics of the above proposed controlled rocking/energy dissipation system with focus on design implications.
منابع مشابه
Seismic Retrofit of Bridge Steel Truss Pier Anchorage Connections
In assessments of the seismic adequacy of existing steel bridges, the steel-to-concrete anchorage connections typically found at the base of steel truss piers can be potentially vulnerable, having little to no ductility and inadequate strength to resist seismic demands. Many other non-ductile failure locations may also exist along the seismic load path. Failure would result in unacceptable perf...
متن کاملSeismic Performance of a Ductile Retrofitted Deck-truss Bridge
Seismic evaluations of many existing deck-truss bridges have revealed the vulnerability of their substructure and members of their superstructure. An innovative retrofit strategy developed by the authors includes replacement of the existing non-ductile end and lower-end bracing with ductile panels by incorporating energy dissipating devices to act as fuses, which can yield and dissipate energy ...
متن کاملSeismic Retrofit of Bridge Steel Truss Piers Using a Controlled Rocking Approach
This paper investigates a seismic retrofit technique that allows bridge steel truss piers to uplift and rock on their foundation. Displacement-based passive energy dissipation devices buckling-restrained braces, or BRBs are implemented at the uplifting location to control the rocking response while providing additional energy dissipation. The hysteretic behavior of the controlled rocking system...
متن کاملControlled Rocking Approach for the Seismic Resistance of Structures
An innovative lateral force resisting system is investigated that allows steel braced frames to uplift and rock on their foundation, partially isolating the frame. Passive energy dissipation devices are implemented at the uplifting location to control the rocking response to within allowable limits. The structure’s gravitational forces provide an inherent restoring force during the rocking resp...
متن کاملBidirectional Seismic Behavior of Controlled Rocking Four-Legged Bridge Steel Truss Piers
The behavior and design of four-legged controlled rocking bridge steel truss piers to three components of seismic excitation are presented in this paper. The controlled rocking approach for seismic protection allows a pier to uplift from its base, limiting the force demands placed on the bridge pier and deck, and can allow the structure to remain elastic during an earthquake, preventing damage ...
متن کامل