Digital templating in hip replacement with and without radiological markers.
نویسندگان
چکیده
Digital templating in hip replacement is commonly performed with radiological markers to determine the magnification. The latter can also be determined by measuring the distance from the x-ray focal spot to the object and the distance from the x-ray focal spot to the radiological cassette or image receptor. We used post-operative radiographs of total hip replacements and hemiarthroplasties from 22 patients to calculate the magnification using both methods. The accuracy of each method was ascertained by measuring the size of the head of the implant projected on to the radiographs and comparing the result with the known size recorded in the medical records. The accuracy was found to be similar with a mean absolute measurement error of 2.6% (SD 1.4; 0.0% to 5.2%) for the radiological marker and 2.8% (sd 2.2; 0.4% to 10.1%) for the distance method (p = 0.75). The mean radiation dose for templating radiographs (pelvis and lateral of the hip) was similar when taken using a radiological marker (328 mSv SD 142) (n = 51) or using the distance measurement method (324 mSv SD 39) (n = 39) (p = 0.90). We conclude that the distance measuring method is as accurate as the radiological marker method, but may avoid some of the disadvantages such as misplacement of the marker or placement outside the radiological field. It may also be more acceptable to the patient and radiographer.
منابع مشابه
Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty.
The use of digital radiography and templating software continues to become more prevalent in orthopedics as the number of total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures increases every year. The purpose of this study was to evaluate the effect of training level on the accuracy of digital templating for primary THA and TKA. Digital radiographs of 97 patients undergoing...
متن کاملAccuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty
PURPOSE Preoperative on-screen templating is a method of using acetate templates on digital images. The aim of the present study was to evaluate the accuracy, intra- and interobserver reliabilities of preoperative on-screen templating using digital radiographs for total hip arthroplasty (THA). MATERIALS AND METHODS Two hundred patients with hip disease who were treated with primary cementless...
متن کاملDisc calibration for digital templating in hip replacement.
Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed...
متن کاملPredictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician.
Digital preoperative templating is increasingly used to predict the correct component size in total hip arthroplasty (THA). Experienced surgeons could avoid the new technique and rely on a digital template done by a younger colleague. We compared the accuracy of preoperative templating between orthopedic residents (group A) and an experienced orthopedic surgeon (group B). In 106 cases, the soft...
متن کاملVariance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography–based templating in primary total hip arthroplasty
Background Preoperative total hip arthroplasty templating can be performed with radiographs using acetate prints, digital viewing software, or with computed tomography (CT) images. Our hypothesis is that 3D templating is more precise and accurate with cup size prediction as compared to 2D templating with acetate prints and digital templating software. Methods Data collected from 45 patients u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 91 4 شماره
صفحات -
تاریخ انتشار 2009