Rapid preconcentration method for the determination of pyrethroid insecticides in vegetable oils and butter fat and simultaneous determination by gas chromatography-electron capture detection and gas chromatography-mass spectrometry.
نویسندگان
چکیده
A simple and rapid solid-phase extraction (SPE)-GC method for the preconcentration and quantification of pyrethroids at low nanogram levels in oils and high fat content samples is presented. The method was studied using seven highly persistent pyrethroid insecticides, viz., cypermethrin, deltamethrin, fenvalerate, cyfluthrin, allethrin, cyhalothrin and permethrin. Preconcentration was achieved by treating the oil samples with methyltrioctylammonium chloride and subsequent elution of the pyrethroid molecules from a graphitized carbon black SPE cartridge using 5 ml of acetonitrile. Pyrethroid quantification was achieved by GC with electron capture detection. Recoveries of the pyrethroids at fortification levels of 0.05-0.5 ppm were 94-105%. Storage on graphitized carbon black for 30 d lowered the recovery of the pyrethroids by only 3-6%. The method compared well with results obtained by a GC-MS method. The relative standard deviation at a concentration level of 0.05-0.2 microgram ml-1 ranged from 1.31 to 5.16%. The limit of detection achieved was 0.002 microgram ml-1 without any additional clean-up and with little interference from lipids during analysis.
منابع مشابه
Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of Disinfection By-products in Water Samples from Advanced Membrane Treatments by Headspace Solid Phase Microextraction and Gas Chromatography-Mass Spectrometry
A headspace-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) method has been developed for the simultaneously determination of 20 disinfection by-products (DBPs) in water samples from reverse osmosis (RO) membranes. Selected compounds belong to different families including: trihalomethanes (THMs), halogenated acetonitriles (HANs), halogenated nitromethanes ...
متن کاملDetection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography
Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...
متن کاملImpact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study
In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 123 9 شماره
صفحات -
تاریخ انتشار 1998