The conversion to metered-dose inhaler with valved holding chamber to administer inhaled albuterol: a pediatric hospital experience.
نویسندگان
چکیده
BACKGROUND Metered-dose inhalers with valved holding chambers (MDI-VHCs) have been shown to be equivalent to small-volume nebulizers (SVNs) for the delivery of bronchodilators in children. At Seattle Children's Hospital and Regional Medical Center we sought to implement the conversion from SVN to MDI-delivered albuterol in nonintubated patients receiving intermittent treatments. METHODS There were 4 distinct interventions used to plan and implement this conversion program: (1) literature review, (2) product selection, (3) policy and operational changes, and (4) staff training. Bronchodilator administration guidelines and clinical pathways for asthma and bronchiolitis were revised to recommend MDI-VHC use in lieu of SVNs. Computerized physician order sets were amended to indicate MDI-VHC as the preferred method of delivering inhaled albuterol in children with asthma and bronchiolitis. Data from administrative case mix files and computerized medication delivery systems were used to assess the impact of our program. RESULTS MDI-VHC utilization increased from 25% to 77% among all non-intensive-care patients receiving albuterol, and from 10% to 79% among patients with asthma (p < 0.001). Duration of stay among patients with asthma was unchanged after conversion to MDI-VHC (p = 0.53). CONCLUSIONS Our program was very successful at promoting the use of MDI-VHC for the administration of albuterol in our pediatric hospital. Duration of stay among patients with asthma did not change during or since the implementation of this program.
منابع مشابه
Oronasal and Tracheostomy Delivery of Soft Mist and Pressurized Metered-Dose Inhalers With Valved Holding Chamber.
BACKGROUND Some pediatric tracheostomized patients who receive inhaled drugs undergo decannulation, and it is unknown whether the dose has to be adjusted. Pressurized metered-dose inhalers (pMDIs) and soft mist inhalers (SMIs) used with valved holding chambers (VHCs) made of non-electrostatic material are available. We hypothesized that using an SMI and changing the delivery route from tracheos...
متن کاملEffect of Interval Between Actuations of Albuterol Hydrofluoroalkane Pressurized Metered-Dose Inhalers on Their Aerosol Characteristics.
BACKGROUND Albuterol hydrofluoroalkane (HFA) either alone or with a valved holding chamber is used to treat bronchoconstriction. Delays between actuation and inhalation are common. Currently, the recommended interval between actuations of an albuterol HFA is 60 s. Using a shorter interval when multiple actuations are ordered will improve productivity in the hospital setting. METHODS We studie...
متن کاملInhaler Use in Hospitalized Patients with Chronic Obstructive Pulmonary Disease or Asthma: Assessment of Wasted Doses.
BACKGROUND Hospitalized patients with chronic obstructive pulmonary disease (COPD) or asthma routinely have inhaled medications ordered for acute and maintenance therapy. Treatment may be administered via metered-dose inhaler (MDI) or dry-powder inhaler (DPI). These products must be appropriately labeled to be released home with the patient or discarded before discharge. OBJECTIVE To assess t...
متن کاملAlbuterol aerosol delivered via metered-dose inhaler to intubated pediatric models of 3 ages, with 4 spacer designs.
OBJECTIVE To determine the amount of albuterol, in various particle size ranges, delivered from a hydrofluoroalkane-propelled metered-dose inhaler (Airomir) in 3 models of pediatric intubation (ages 8 months, 4 years, and 16 years) using 4 types of aerosol reservoir: 3 spacers (ACE, AeroChamber HC MV, metal NebuChamber without 1-way valve) and 1 holding chamber (metal NebuChamber with 1-way val...
متن کاملReview: beta agonist delivery by metered dose inhaler with a valved holding chamber (compared with a nebuliser) reduces admissions in preschool children and infants with acute asthma or wheezing.
Castro-Rodriguez JA, Rodrigo GJ. Beta-agonists through metered-dose inhaler with valved holding chamber versus nebulizer for acute exacerbation of wheezing or asthma in children under 5 years of age: a systematic review with meta-analysis. J Pediatr 2004;145:172–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 53 3 شماره
صفحات -
تاریخ انتشار 2008