Kinematic analysis following implantation of the PRESTIGE LP

نویسندگان

  • Izabela Kowalczyk
  • Navjot Chaudhary
  • Neil Duggal
چکیده

BACKGROUND The clinical success of cervical arthroplasty hinges on the ability to preserve or improve the biomechanics of the functional spinal unit. The purpose of this study was to conduct a radiologic assessment of kinematic parameters preimplantation and postimplantation of the PRESTIGE LP Cervical Disc System (Medtronic, Memphis, Tennessee). METHODS A total of 120 radiographs of 20 patients following single-level implantation of the PRESTIGE LP were retrospectively reviewed. Static and dynamic radiologic assessments were performed before surgery and at 1 year postoperation. Kinematic parameters including range of motion (ROM), horizontal translation, center of rotation (COR X, Y), anterior disc height and posterior disc height, and disc angle and shell angle were assessed for each spinal level using quantitative motion analysis software. Clinical outcomes were assessed using the short form health survey physical component scores and mental component scores. RESULTS The mean physical component scores and mental component scores of the short form health survey (SF-36) improved significantly following surgery. At 1 year postoperation, ROM, translation, and COR X were preserved. The COR Y shifted superiorly from 3.17 ± 2.08 mm preoperation to 0.98 ± 2.23 mm postoperation (P < .001). The anterior disc height and posterior disc height were significantly increased following surgery (3.97 ± 1.01 to 4.78 ± 1.11 mm and 3.04 ± 0.69 to 3.66 ± 0.61 mm, respectively; P < .01). The preoperative disc angle was 3.32° ± 2.92° and the postoperative shell angle was 1.11° ± 4.29°, with a mean change of -2.22° ± 4.63° (P < .05). CONCLUSIONS The PRESTIGE LP maintained preoperative ROM, translation, and COR X values. The postoperative COR Y value changed significantly by shifting superiorly, accompanied by an increase in DH. There was a loss of lordosis at the level of surgery, with the PRESTIGE LP endplates having an almost parallel endplate configuration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-vivo study of osseointegration in Prestige LP cervical disc prosthesis

BACKGROUND A study was designed to quantify the extent of porous osseointegration at the prosthesis-bone interface in the Prestige LP prosthesis containing a plasma-sprayed titanium coating. METHODS Using an anterior surgical approach, cervical disc arthroplasty was performed in 8 mature male goats at the C3-C4 segment, followed by implantation of the Prestige LP prosthesis. The vertebral spe...

متن کامل

Biomechanical Analysis of a Novel Prosthesis Based on the Physiological Curvature of Endplate for Cervical Disc Replacement

STUDY DESIGN Biomechanical analysis of a novel prosthesis based on the physiological curvature of endplate was performed. OBJECTIVE To compare the biomechanical differences between a novel prosthesis based on the physiological curvature of the endplate and the Prestige LP prosthesis after cervical disc replacement (CDR). SUMMARY OF BACKGROUND DATA Artificial disc prostheses have been widely...

متن کامل

Biomechanical evaluation of cervical disc replacement with a novel prosthesis based on the physiological curvature of endplate

BACKGROUND Most of the current available cervical disc prostheses present a flat surface instead of an arcuate surface which is most similar to the morphology of cervical endplate. Therefore, we designed a novel prosthesis (Pretic-I, Trauson) based on the physiological curvature of the cervical endplate. Biomechanical evaluation of cervical disc replacement (CDR) with this novel prosthesis was ...

متن کامل

Dear Editors and Reviewers: Thank you for your letter and for the reviewer’s comments concerning our manuscript entitled “Total disc replacement with the Prestige LP cervical disc in a Caprine model”. Those comments

Thank you for your letter and for the reviewer’s comments concerning our manuscript entitled “Total disc replacement with the Prestige LP cervical disc in a Caprine model”. Those comments are all valuable and very helpful for revising and improving our paper, as well as the important guiding significance to our researches. We have studied comments carefully and have made corrections which we ho...

متن کامل

O-30: Comparing Expression Patterns of Endometrial Genes in Implantation Failures and Recurrent Miscarriages with Fertile Couples Following ICSI/IVF Using in Silico Analysis

Background: To screen and diagnose patients with recurrent abortions and implantation failure after IVF/ICSI, differentially expressed genes of endometrium through DNA microarrays were monitored. Materials and Methods: Microarray expression profile of GSE26787 dataset from GEO database was used to analyze gene expression profiles of 15 endometrial biopsy samples- five from control fertile (CF) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013