The dose penumbra of a custom‐made shield used in hemibody skin electron irradiation
نویسندگان
چکیده
We report our technique for hemibody skin electron irradiation with a custom-made plywood shield. The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a plywood shield placed at 50 cm from the patient. The shield is made of three layers of stan-dard 5/8'' thick plywood (total thickness of 4.75 cm) that are clamped securely on an adjustable-height stand. Gafchromic EBT3 films were used in assessing the shield's transmission factor and the extent of the dose penumbra region for two different shield-phantom gaps. The shield transmission factor was found to be about 10%. The width of the penumbra (80%-to-20% dose falloff) was measured to be 12 cm for a 50 cm shield-phantom gap, and reduced slightly to 10 cm for a 35 cm shield-phantom gap. In vivo dosimetry of a real case confirmed the expected shielded area dose.
منابع مشابه
A dosimetric study of deep skin electron therapy with overlapping stationary radiation fields – A case report
Background: For radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (Angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. The details of dosimetry, clinical dose measurements are presented. Materials and Methods: The treatment planned with 6 overlapping 9 MeV electron fields in ...
متن کاملFabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies
Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...
متن کاملDesign of a generally applicable abdominal shield for reducing fetal dose during radiotherapy of common malignancies in pregnant patients
Background: In most cancer cases, the treatment choice for a pregnant patient is radiotherapy. In these patients, the abdomen is usually not exposed therefore fetus exposure is due to peripheral dose (PD). The purpose of this study was to estimate the fetal dose (the maximum PD in each pregnancy stage) for modalities available and to fabricate and evaluate a generally applicable fetal ...
متن کاملTotal skin electron therapy (TSET): Monte Carlo Simulation and implementation
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
متن کاملGenerating a Homogeneous Dose Distribution in the Junction Region between Two Adjacent Fields in Electron Beam Therapy
Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new met...
متن کامل