A Maximum-likelihood Approach to Pet Emission/attenuation Image Registration

نویسندگان

  • W. L. S. Costa
  • D. R. Haynor
  • R. M. Haralick
  • T. K. Lewellen
چکیده

An algorithm for retrospective registration of PET emission and attenuation images is introduced based upon the assumption that no activity should be present outside the body. Since the attenuation image defines anatomy, it is segmented to identify a foreground template of the subject. This template is mapped to the emission image by a geometric transformation, and the emission image pixels that do not correspond to the foreground template are considered the background pixels for that transformation. An optimal geometric transformation mapping the foreground template to the emission image is sought by maximizing the likelihood of the background emission image pixels given a background intensity distribution; this background intensity distribution is estimated from the background pixels for the initial position of the template. The current implementation of the algorithm is confined to 2-D rigid motion, although these constraints are not fundamental to the method. In a preliminary phantom study where the phantom was moved between the acquisition of emission and attenuation data, the registration algorithm predicted the rotation to within five degrees (worst case) and usually to within three degrees, and it predicted the translation to within one and a half pixels; it predicted the rotation to within one degree and the translation within one pixel when performed on images reconstructed with a matching attenuation image. Possible improvements to the algorithm are suggested, based on the observation that the predicted motion is biased by the attenuation correction artifact in the images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions.

UNLABELLED CT-based attenuation correction is a widely used option in commercial PET/CT scanners. However, as a result of a nonsimultaneous acquisition and differences in temporal resolution between both modalities, a potential misregistration between the PET and CT, especially in the thorax and the upper abdomen, can be found. We observed a substantial number of apparent perfusion defects in s...

متن کامل

Algorithms for joint estimation of attenuation and emission images in PET

tistical model f31. Both of these methods employ a sequenIn positron emission tomography (PET), positron emission from radiolabeled compounds yields two high energy photons emitted in opposing directions. However, often the photons are not detected due to attenuation within the patient. This attenuation is nonuniform and must be corrected to obtain quantitatively accurate emission images. To me...

متن کامل

PET, CT, and MR Image Registration of the Rat Brain and Skull

Spatially registered positron emission tomography (PET), computed tomography (CT), and magnetic resonance (MR) images of the same small animal offer potential advantages over PET alone: CT images should allow accurate, nearly noise-free correction of the PET image data for attenuation; the CT or MR images should permit more certain identification of structures evident in the PET images; and CT ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1993