Magnetic and Impedance Measurements for the Detection of Spreading Depression at a Distance
نویسنده
چکیده
3. With neurosurgical exposure of vulnerable brain tissue, the monitoring of disturbances such as SD beneath the surface, causing local changes of electrical impedance, may be carried out through the application of current and the measurement of voltage changes restricted to the tissue surface. 4. In neurosurgical monitoring an important distinction must be made between mild superficial disturbances and deeper profound disturbances, which in some respects produce similar signals at the surface. Information about the depth of the disturbance can be extracted from multiple surface impedance measurements, and may assist in making this distinction.
منابع مشابه
The Neuroprotective Effects of Long-Term Repetitive Transcranial Magnetic Stimulation on the Cortical Spreading Depression-induced Damages in Rat’s Brain
Introduction: Cortical Spreading Depression (CSD) is a propagating wave of neural and glial cell depolarization with important role in several clinical disorders. Repetitive Transcranial Magnetic Stimulation (rTMS) is a potential tool with preventive treatment effects in psychiatric and neuronal disorders. In this paper, we study the effects of rTMS on CSD by using behavioral and histological a...
متن کاملStress Corrosion Cracking Detection of Sensitized Stainless Steel 304 in Chloride Media by Using Electrochemical Impedance Spectroscopy (EIS)
Electrochemical impedance spectroscopy (EIS) was used to detect stress corrosion cracking (SCC) in stainless steel 304 alloy exposed to an aqueous environment at 120 °C. Stainless steel 304 alloy as u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. U-bended samples were prepared according to ASTM G30. EIS measurements were always performed simultaneously o...
متن کاملEvaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging
Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...
متن کاملA new interval approach for setting the distance relay zones to achieve perfect selectivity and maximum sensitivity
In this paper, an interval approach is presented to achieve perfect selectivity and maximum sensitivity in distance relay zones, considering uncertainties. For this purpose, first, the uncertainties affecting the settings of the three zones of a distance relay are discussed. Then, by using the Monte-Carlo simulation, the uncertainties are modelled and the impedances seen by the distance relay a...
متن کاملApplications of Impedance Plane and Magnetic Differential Permeability in Microstructural Characterization of AISI D2 Tool Steel
Two nondestructive electromagnetic/magnetic techniques including hysteresis loop and eddy current methodologies have been used to characterize microstructural changes of AISI D2 cold work tool steel as a result of quench and tempering treatments. To measure the fraction retained austenite in quenched microstructure, six specimens were austenitized in the range of 1000-1130 °C. Samples austenit...
متن کامل