Ultraviolet thermal lensing detection of amino acids.

نویسندگان

  • Fang Yu
  • Alexander A Kachanov
  • Serguei Koulikov
  • Ann Wainright
  • Richard N Zare
چکیده

Thermal lensing (TL) permits ultra-sensitive measurements of optical absorption of analytes in very small liquid volumes. We report the construction and use of a TL detector based on pulsed ultraviolet (UV) laser excitation (266 nm). We applied this detector to quantitate amino acids using capillary electrophoresis (CE) as a means of separation. Sixteen individual amino acids are readily detected, but the signal has a complex dependence on intensity caused by the combination of (1) one-photon absorption; (2) two-photon absorption (TPA); and (3) photodestruction of amino acid molecules in the focus of the laser beam. An aqueous solution containing tyrosine, tryptophan, and cysteine is electrophoretically separated and the individual amino acids are detected by UV TL. The estimated limit of detection is 7 microM for tyrosine, 2.5 microM for tryptophan and 33 microM for cysterine, which translates into 0.35 fmol for tyrosine, 0.125 fmol for tryptophan, and 1.65 fmol for cysteine in the 140pL detection volume. It is found that two-photon absorption of water and the formation of color centers in the fused silica walls of the flowcell can contribute a significant, drifting background signal, but this interference can be minimized by selecting an appropriate focus condition and excitation-detection geometry. We suggest that as UV laser sources become available, UV TL may become a method of choice for measuring the concentrations of many analytes in different separation formats in which the volume is highly limited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of topological indices to predict thermodynamic properties of amino acids derivatives

In the present investigation the applicability of various topological indices are tested for the QSPR study on 80 amino acids derivatives. Relationship between the Randic' (1X), Balaban (J), Szeged (Sz), Harary (H), Wiener (W), Hyper-Wiener (WW) and Wiener Polarity (WP) indices to the thermodynamic Properties such as thermal energy Eth (J/mol) and heat capacity (CV J/mol. K) of amino acids is r...

متن کامل

Ultraviolet detection of amino acids based on their on-column conjugation with cupric cation using a disposable electrophoresis microdevice.

A method for fast sensitive ultraviolet detection of amino acids was developed with a disposable electrophoresis microdevice. The microdevice was conveniently constructed by fixing a fused-silica capillary with a sampling fracture to a printed circuit board. During the separation process, the on-column conjugation of amino acids with cupric cation led to the ultraviolet absorption at 232 nm tha...

متن کامل

ATTOMOLE DETERMINATION OF PHENYL THZOHYDANTOrN DERNATNES OF AMINO ACIDS BY CAPILLARY ZONE ELECTROPHORESLS SEPARATION AND ULTRAVIOLET- LASER EXCITED THERMO.OPTICAL ABSORBANCE DETECTION

Capillary zone electrophoresis provides a rapid method for the analysis of minute amounts of amino acids. A laser-based absorbance technique is used to determine phenylthiohydantoin amino acids with detection limits of 10.15 mot; separation of 20 amino acids, based on micelle modified zone electrophoresis, requires 13 minutes. The amino acid sequence of a protein is of fundamental value in the ...

متن کامل

Comparing the analytical potential of PAS, PDS, TL and PTPS for trace detection of pesticides in water

Performances of four related techniques i.e., photoacoustic spectroscopy, photothermal deflection, thermal lensing, and photothermal phase shift spectroscopy have been compared to the conventional beam transmittance spectrophotometry. This concerns to the analytical potential in studies of environmental pollutants. Solutions of pesticides in water are used as specimens in this study. Spectropho...

متن کامل

Stroboscopic Surface Thermal Lensing for Fast Detection of Thermal Defects in Large-Scaled Coating Films

A stroboscopic surface thermal lensing (SSTL) system for the fast detection of thermal-induced defects in large-scaled optical coating films was constructed. The SSTL signal was generated by a set of double-modulators and captured by a high speed matrix camera, respectively. The spot size of both pump laser and probe laser expanded for larger detection area was finished in a single step. Based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1216 16  شماره 

صفحات  -

تاریخ انتشار 2009