High resolution mass spectrometry.

نویسندگان

  • Feng Xian
  • Christopher L Hendrickson
  • Alan G Marshall
چکیده

Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to approximately 400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (C(c)H(h)N(n)O(o)S(s)P(p)...) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass ( approximately 100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution Mass Spectrometry and Accurate Mass Measurements with Emphasis on the Characterization of Peptides and Proteins by Matrix-assisted Laser Desorption/Ionization Time-of-Ñight Mass Spectrometry

Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciÐc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-Ñight (TOF) methods are discussed. Recent high-resolution TOF measurements on peptides and proteins, ionized by matrix-assisted laser desorption/ionization ...

متن کامل

Design and performance of a high resolution electrospray ion source for a magnetic sector mass spectrometer with a heated capillary inlet.

The design and performance of an electrospray ion source for a high resolution magnetic sector mass spectrometer that utilizes a heated capillary has been presented. Low pressure, high sensitivity, stable electrospray, low flow rates, and low electronic noise were important factors in achieving high resolution electrospray mass spectrometry. A unit mass resolution has been achieved for biomolec...

متن کامل

Accurate mass measurement of DNA oligonucleotide ions using high-resolution time-of-flight mass spectrometry.

Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measure...

متن کامل

Secondary Ion Mass Spectrometry Imaging of Dictyostelium discoideum Aggregation Streams

High resolution imaging mass spectrometry could become a valuable tool for cell and developmental biology, but both, high spatial and mass spectral resolution are needed to enable this. In this report, we employed Bi3 bombardment time-of-flight (Bi3 ToF-SIMS) and C60 bombardment Fourier transform ion cyclotron resonance secondary ion mass spectrometry (C60 FTICR-SIMS) to image Dictyostelium dis...

متن کامل

Polychlorinated biphenyls (PCBs) analysis using a miniaturized high-resolution time-of-flight mass spectrometer "MULTUM-S II".

In this study, we conducted polychlorinated biphenyls (PCBs) analysis using fast gas chromatography (GC)/high-resolution mass spectrometry (HRMS). Mass spectrometry (MS) was performed with a miniature multi-turn time-of-flight (TOF) analyzer called "MULTUM-S II". MULTUM-S II is truly a portable high resolution mass spectrometer. The mass spectrometer's high resolution capability is due to its t...

متن کامل

Improved resolution in the detection of oligonucleotides up to 60-mers in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using pulsed-delayed extraction with a simple high voltage transistor switch.

Pulsed-delayed extraction using a simple high voltage transistor switch together with various sample purification approaches were used to enhance the resolution in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of oligonucleotides up to 60 bases long. This switch can provide a 0-3 kV voltage pulse with a 75 ns fall time. A resolution of 500-900 was ty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 2  شماره 

صفحات  -

تاریخ انتشار 2008