Aroylthioureas: new organic ionophores for heavy metal ion selective electrodes. A nuclear magnetic resonance study.

نویسندگان

  • E Otazo-Sánchez
  • P Ortiz-del-Toro
  • O Estévez-Hernández
  • L Pérez-Marín
  • I Goicoechea
  • A Cerón Beltran
  • J R Villagómez-Ibarra
چکیده

The 1H and 13C NMR spectra of four series of 1-aroylthiourea derivatives in DMSO-d6 are reported. The NH signals for 3-alkyl substituted aroylthioureas are identified by their multiplicity and by homonuclear irradiation experiments. Correlation analyzes are made for NH, CO and CS signals in order to determine the best way to modulate the nucleophilic character of the CS group, as thioureas are well-known ionophore groups. Almost all 1,3-substituted thioureas (Series 2-4) show the reported chelated structure with the exception of those with CF3, CN and NO2 groups. Pyridine group promote a different equilibrium in solution. The fragment -CO-NH- transmits poorly the electronic effects of substituents in the aroylgroup.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions

In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...

متن کامل

Potentiometric determination of silver(I) by selective membrane electrode based on derivative of porphyrin.

The performance of silver metal complexes with meso-tetraphenylporphyrin ([H2T(4-CH3)]PP) as ionophores for ion-selective electrodes was studied. The electrode exhibited linear response with Nernstian slope of 59.2 +/- 1.0 mV per decade within the concentration range of 1.0 x 10(-7)-1.0 x 10(-1) M silver ions. The limit of detection as determined from the intersection of the extrapolated linear...

متن کامل

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Potassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives

Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...

متن کامل

Modeling Magnetic Field in Heavy ion Collisions Using Two Different Nuclear Charge Density Distributions

By studying the properties of matter during heavy-ion collisions, a better understanding of the Quark-Gluon plasma is possible. One of the main areas of this study is the calculation of the magnetic field, particularly how the values of conductivity affects this field and how the field strength changes with proper time. In matching the theoretical calculations with results obtained in lab, two diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

دوره 58 10  شماره 

صفحات  -

تاریخ انتشار 2002