Cost-effectiveness of implantable cardioverter-defibrillators.

نویسندگان

  • G Boriani
  • M Biffi
  • C Martignani
  • M Gallina
  • A Branzi
چکیده

BACKGROUND Eight randomized trials have evaluated whether the prophylactic use of an implantable cardioverter-defibrillator (ICD) improves survival among patients who are at risk for sudden death due to left ventricular systolic dysfunction but who have not had a life-threatening ventricular arrhythmia. We assessed the cost-effectiveness of the ICD in the populations represented in these primary-prevention trials. METHODS We developed a Markov model of the cost, quality of life, survival, and incremental cost-effectiveness of the prophylactic implantation of an ICD, as compared with control therapy, among patients with survival and mortality rates similar to those in each of the clinical trials. We modeled the efficacy of the ICD as a reduction in the relative risk of death on the basis of the hazard ratios reported in the individual clinical trials. RESULTS Use of the ICD increased lifetime costs in every trial. Two trials--the Coronary Artery Bypass Graft (CABG) Patch Trial and the Defibrillator in Acute Myocardial Infarction Trial (DINAMIT)--found that the prophylactic implantation of an ICD did not reduce the risk of death and thus was both more expensive and less effective than control therapy. For the other six trials--the Multicenter Automatic Defibrillator Implantation Trial (MADIT) I, MADIT II, the Multicenter Unsustained Tachycardia Trial (MUSTT), the Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) trial, the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) trial, and the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)--the use of an ICD was projected to add between 1.01 and 2.99 quality-adjusted life-years (QALY) and between 68,300 dollars and 101,500 dollars in cost. Using base-case assumptions, we found that the cost-effectiveness of the ICD as compared with control therapy in these six populations ranged from 34,000 dollars to 70,200 dollars per QALY gained. Sensitivity analyses showed that this cost-effectiveness ratio would remain below 100,000 dollars per QALY as long as the ICD reduced mortality for seven or more years. CONCLUSIONS Prophylactic implantation of an ICD has a cost-effectiveness ratio below 100,000 dollars per QALY gained in populations in which a significant device-related reduction in mortality has been demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Life expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertrophic cardiomyopathy

CRD summary The study examined the cost-effectiveness of using implantable cardioverter/defibrillator (ICD) insertion or amiodarone therapy for the prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM), with no history of cardiac arrest but a significant risk of SCD. The study results support the cost-effectiveness of ICD insertion from the perspective of t...

متن کامل

Cost-Effectiveness of Implantable Cardioverter–Defibrillators

From Duke Clinical Research Institute, Duke University, Durham, N.C. (G.D.S.); the Department of Health Research and Policy, School of Medicine (M.A.H.), and the Center for Primary Care and Outcomes Research, Department of Medicine (M.A.H., D.K.O.), Stanford University, Stanford, Calif.; and the Veterans Affairs Palo Alto Health Care System, Palo Alto, Calif. (D.K.O.). Address reprint requests ...

متن کامل

Life expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertrophic cardiomyopathy

CRD summary The study examined the cost-effectiveness of using implantable cardioverter/defibrillator (ICD) insertion or amiodarone therapy for the prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM), with no history of cardiac arrest but a significant risk of SCD. The study results support the cost-effectiveness of ICD insertion from the perspective of t...

متن کامل

The Cost Effectiveness of Implantable Cardioverter-Defibrillators

OBJECTIVES We sought to evaluate the cost implications of the implantable cardioverter-defibrillator (ICD), using utilization, cost, and survival data from the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II. BACKGROUND This trial showed that prophylactic implantation of a defibrillator reduces the rate of mortality in patients who experienced a previous myocardial infarction ...

متن کامل

Cardiac imaging in syndrome X: the problem of "reverse redistribution'.

patient with cardiac arrest, as initial presentation of the underlying cardiac disease, who receives an implantable cardioverter-defibrillator, cost cannot be evaluated, unless the first line therapeutic option for these patients is not an implantable cardioverter-defibrillator. Another approach could be to randomize these patients to an implantable cardioverter-defibrillator or to other forms ...

متن کامل

Primary prevention of sudden cardiac death using implantable cardioverter defibrillators.

Despite substantial advances in prevention and treatment of cardiovascular diseases, sudden cardiac death (SCD) remains a leading cause of death in industrialized countries. Implantable cardioverter defibrillator (ICD) has been demonstrated to be an attractive option for primary prevention of SCD in high-risk patients. This review discusses the progress in the risk stratification for selecting ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 353 14  شماره 

صفحات  -

تاریخ انتشار 2001