Improving the precision of QT measurements.
نویسندگان
چکیده
BACKGROUND Accurate and precise QT interval measurement is very important for both regulatory and drug developmental decision making. These measurements are often made using a manual or semi-automated technique, and the associated variability necessitates sample sizes of around 50 to 70 subjects in thorough QT/QTc studies. The purpose of this study was to compare the reproducibility and precision of a semi-automated (SA) method and a high-precision (HPQT) technique for ECG extraction and QT interval measurement on two thorough QT/QTc (TQT) studies conducted in compliance with ICH E14. METHODS Data from 35 healthy subjects from two different crossover TQT studies on treatment with placebo and moxifloxacin was analyzed. Both methods examined the RR and QT intervals measured in lead II or the lead with the highest quality T-wave on a single beat basis using the QT algorithm included in the COMPAS software package. ECGs were measured at a protocol-specific timepoint. RESULTS The effect of moxifloxacin on the QTc interval was highly reproducible in the two studies, and assay sensitivity was met with both methods. Pairwise comparison of QTcF values between methods demonstrated high agreement with no bias, small mean differences (below 1.5 ms) and narrow limits of agreement. HPQT improved the precision of the QTc measurement by 31% in Study I (standard deviation of DQTcF: SA 8.9 ms; HPQT 6.3 ms) and by 15% in Study II (SD: SA 9.7 ms; HPQT 8.3 ms). CONCLUSIONS The HPQT QT measurement technique detected the effect induced by moxifloxacin with the same accuracy as SA techniques, and with clearly improved precision. More precise QTc measurement has important implications in terms of lowering the likelihood of false positive results and/or reducing the sample size in TQT studies, as well as improving the utility of QT assessment in early clinical development.
منابع مشابه
Water Velocity Measurements in Open Channels Using Volumetric Current Meter (VCM)
An innovative Volumetric Current Meter (VCM) was designed in order to allow quick velocity measurements in open channels. At first, the coefficient of velocity (Cv) of the device was determined through calibration under different water velocities in the laboratory. The measurement performance was verified by measurements performed in similar flows in irrigation channels using an ordinary curren...
متن کاملAccuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements
Background and Purpose: Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...
متن کاملOptimization of 241Am-Be emission direction in neutron porosity tools for improving the precision in determining the porosity in calcite formation
Investigation of Hydrocarbon reservoir is important, so it is essential to predict and explore them precisely. One of the methods is well logging, which can transfer the probe or tool in the well to measure one or more characteristics. Nuclear well logging includes radioisotope source and at least one detector. In this work, emission direction of neutrons from the 241Am-Be neutron source toward...
متن کاملThe Application of Root Mean Square Electrocardiography (RMS ECG) for the Detection of Acquired and Congenital Long QT Syndrome
BACKGROUND Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential d...
متن کاملChanges in QT interval before and after hemodialysis
Background: Cardiovascular mortality and morbidity are high in chronic renal failure (CRF) patients. Increased dispersion of QT intervals is known to predispose to ventricular arrhythmias and sudden cardiac death. This study was conducted to assess the effect of hemodialysis (HD) on corrected QT (QTc) intervals and their dispersions (QTd) in chronic hemodialyzed patients. Methods: Fifty-eight p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology journal
دوره 18 4 شماره
صفحات -
تاریخ انتشار 2011