A quantitative LC-MS/MS method for comparative analysis of capture-antibody affinity toward protein antigens.

نویسندگان

  • Mark S Lowenthal
  • Hugo Gasca-Aragon
  • John E Schiel
  • Nathan G Dodder
  • David M Bunk
چکیده

A mass spectrometry-based antibody selection procedure was developed to evaluate optimal 'capture' monoclonal antibodies that can be used in a variety of analytical measurement applications. The isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) methodology is based on the use of multiple-reaction monitoring of tryptic peptide fragments derived from protein antigens. A panel of monoclonal antibodies (mAb) was evaluated based on a quantitative determination of relative binding affinity to human cardiac troponin I following immunoprecipitation. Dissociation constants (K(d)) were determined for 'bound mAb-antigen' vs. 'unbound antigen' using non-linear regression analysis. Relative quantification of both antigen and antibody was based on the use of stable isotope-labeled synthetic peptides as internal standards. Optimal 'capture' mAbs were determined through evaluation of relative K(d) constants of all monitored peptide transitions. A panel of six pre-screened candidate capture mAbs was concluded to consist of two subsets of mAbs, each with statistically equivalent K(d) constants as determined using NIST Standard Reference Material (SRM) 2921 - Human Cardiac Troponin Complex. This ID LC-MS/MS method is shown to be capable of quantitatively differentiating mAbs based on relative binding affinities. Selection of optimal capture mAbs can be applied toward a number of analytical applications which require metrological traceability and unbiased quantification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference measurement procedure development for C-reactive protein in human serum.

This paper describes the development of a reference measurement procedure to quantify human C-reactive protein (CRP) in serum using affinity techniques prior to tryptic digestion and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the certification of reference materials in clinically relevant ranges. The absence of a suitable internal standard for the CRP measurement, necessary t...

متن کامل

Antibody-free workflows for protein quantification by LC-MS/MS.

Antibody-free approaches for quantitative LC-MS/MS-based protein bioanalysis are reviewed and critically evaluated, and compared with the more widely used immunoaffinity-based approaches. Antibody-free workflows will be divided into four groups and discussed in the following order: direct analysis of signature peptides after proteolytic digestion; enrichment of target proteins and signature pep...

متن کامل

Accurate qualitative and quantitative proteomic analysis of clinical hepatocellular carcinoma using laser capture microdissection coupled with isotope-coded affinity tag and two-dimensional liquid chromatography mass spectrometry.

Laser capture microdissection (LCM) is a powerful tool that enables the isolation of specific cell types from tissue sections, overcoming the problem of tissue heterogeneity and contamination. This study combined the LCM with isotope-coded affinity tag (ICAT) technology and two-dimensional liquid chromatography to investigate the qualitative and quantitative proteomes of hepatocellular carcinom...

متن کامل

Complementary analysis of the Mycobacterium tuberculosis proteome by two-dimensional electrophoresis and isotope-coded affinity tag technology.

Classical proteomics combined two-dimensional gel electrophoresis (2-DE) for the separation and quantification of proteins in a complex mixture with mass spectrometric identification of selected proteins. More recently, the combination of liquid chromatography (LC), stable isotope tagging, and tandem mass spectrometry (MS/MS) has emerged as an alternative quantitative proteomics technology. We ...

متن کامل

Semi-supervised LC/MS alignment for differential proteomics

MOTIVATION Mass spectrometry (MS) combined with high-performance liquid chromatography (LC) has received considerable attention for high-throughput analysis of proteomes. Isotopic labeling techniques such as ICAT [5,6] have been successfully applied to derive differential quantitative information for two protein samples, however at the price of significantly increased complexity of the experime...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 879 26  شماره 

صفحات  -

تاریخ انتشار 2011