Dependence of negative-mode electrospray ionization response factors on mobile phase composition and molecular structure for newly-authenticated neutral acylsucrose metabolites.

نویسندگان

  • Banibrata Ghosh
  • A Daniel Jones
چکیده

Authentic standards of known concentrations serve as references for accurate absolute quantification of plant metabolites using liquid chromatography/mass spectrometry (LC/MS). However, often such standards are not commercially available or not amenable for custom syntheses. Despite the widespread use of electrospray ionization for metabolite analyses, the fundamentals needed for reliable prediction of molecular response factors have yet to be explored in detail for analytes that lack ionized functional groups. In order to lay a foundation for quantifying unknown neutral plant metabolites in absence of authentic standards, sub-milligram quantities of purified homologous acylsucrose metabolites were authenticated by subjecting each to basic hydrolysis and quantifying the sucrose product using stable-isotope dilution ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with multiple reaction monitoring (MRM). Once authenticated, molar response factors of [M + formate](-) ions for the acylsucrose metabolites were determined at different mobile phase compositions ranging from 40%-80% acetonitrile, and demonstrated relationships of response factors with mobile phase composition and metabolite structural features including nonpolar surface areas, the length of the longest acyl chain, and the number of hydroxyl groups. This approach was employed to calculate predicted response factors for three authenticated acylsucroses based on mean values for all isomers with a common number of total acyl carbon atoms. Absolute UHPLC-MS quantification was performed on these three metabolites in an extract from leaves of the wild tomato Solanum habrochaites LA1777, yielding deviations of 26%, 6.7%, and 7.3% from values established using compound-specific response factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 19  شماره 

صفحات  -

تاریخ انتشار 2015