Impedance analysis of the organ of corti with magnetically actuated probes.

نویسندگان

  • Marc P Scherer
  • Anthony W Gummer
چکیده

An innovative method is presented to measure the mechanical driving point impedance of biological structures up to at least 40 kHz. The technique employs an atomic force cantilever with a ferromagnetic coating and an external magnetic field to apply a calibrated force to the cantilever. Measurement of the resulting cantilever velocity using a laser Doppler vibrometer yields the impedance. A key feature of the method is that it permits measurements for biological tissue in physiological solutions. The method was applied to measure the point impedance of the organ of Corti in situ, to elucidate the biophysical basis of cochlear amplification. The basilar membrane was mechanically clamped at its tympanic surface and the measurements conducted at different radial positions on the reticular lamina. The tectorial membrane was removed. The impedance was described by a generalized Voigt-Kelvin viscoelastic model, in which the stiffness was real-valued and independent of frequency, but the viscosity was complex-valued with positive real part, which was dependent on frequency and negative imaginary part, which was independent of frequency. There was no evidence for an inertial component. The magnitude of the impedance was greatest at the tunnel of Corti, and decreased monotonically in each of the radial directions. In the absence of inertia, the mechanical load on the outer hair cells causes their electromotile displacement responses to be reduced by only 10-fold over the entire range of auditory frequencies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TIME OPTIMAL SLEW MANEUVER OF MAGNETICALLY ACTUATED LEO SATELLITES

Conventional magnetic attitude control methodologies require several orbital periods to accomplish the required attitude maneuvers due to the existence of an uncontrollable axis, namely the local Earth’s magnetic field vector. Since in some attitude maneuver missions the elapsed time is of critical importance, those time-consuming controllers are not satisfactory and we need a much faster contr...

متن کامل

Vibration pattern of the organ of Corti up to 50 kHz: evidence for resonant electromechanical force.

Electromechanical force derived from the soma of the outer hair cell has long been postulated as the basis of the exquisite sensitivity of the cochlea. The problem with this postulate is that the electrical source and mechanical load for the electromechanical outer hair cell might be severely attenuated and phase-shifted by the electrical impedance of the cell and the mechanical impedance of th...

متن کامل

Impedance Control of Robots Using Voltage Control Strategy Revisited

In this note, we show that the impedance control strategy proposed in the paper is not feasible from practical implementation point of view. Next, a robust impedance controller is proposed for electrically driven robots using Fourier series (FS). The fact that robots' actuators have limited voltage is also considered in controller design procedure. In comparison with other impedance controllers...

متن کامل

External control of dissipation in a nanometer-scale radiofrequency mechanical resonator

We demonstrate a technique by which the quality factor of a magnetically-actuated mechanical resonator is controlled by an external electrical circuit. Modulation of this parameter is achieved by local variation of the electrical impedance presented to the resonator at its resonance frequency. We describe a theory that explains this result as arising from eddy currents in the external electrica...

متن کامل

Theoretical and Experimental Study on Magnetically- Actuated Micromirrors for Electromagnetic Nde

Magnetically-actuated Micromirrors as Micro-electromechanical devices have exhibited their superiority over other magnetic sensing techniques in terms of high sensitivity and high spatial resolution, which is favoured not only by quantitative measurement but also imaging of magnetic field distribution. In our research into magnetic field sensing and imaging, a 2D magnetic field sensing system w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biophysical journal

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2004