Stereoscopic liver surface reconstruction
نویسندگان
چکیده
The paper presents a practical approach to measuring liver motion, both respiratory and laparoscopic, with a tool guided in the operating room. The presented method is based on standard operating room equipment, i.e. rigid laparoscopic cameras and a single incision laparoscopic surgery trocar. The triangulation algorithm is used and stereo correspondence points are marked manually by two independent experts. To calibrate the cameras two perpendicular chessboards, a pinhole camera model and a Tsai algorithm are used. The data set consists of twelve real liver surgery video sequences: ten open surgery and two laparoscopic, gathered from different patients. The setup equipment and methodology are presented. The proposed evaluation method based on both calibration points of the chessboard reconstruction and measurements made by the Polaris Vicra tracking system are used as a reference system. In the analysis stage we focused on two specific goals, measuring respiration and laparoscopic tool guided liver motions. We have presented separate examples for left and right liver lobes. It is possible to reconstruct liver motion using the SILS trocar. Our approach was made without additional position or movement sensors. Diffusion of cameras and laser for distance measurement seems to be less practical for in vivo laparoscopic data, but we do not exclude exploring such sensors in further research.
منابع مشابه
3D Surface Reconstruction from Stereoscopic Image Sequences
A stereoscopic scene analysis system for 3–D modeling of objects from stereoscopic image sequences is described. A dense map of 3–D surface points is obtained by image correspondence, object segmentation, interpolation, and triangulation. Emphasis is put on the accurate measurement of image correspondences from grey level images. The surface geometry of each scene object is approximated by a tr...
متن کاملIn vitro evaluation of stereoscopic liver surface reconstruction
INTRODUCTION Tracking abdominal motion of organs is an important factor in image-guided navigation systems. The paper presents the evaluation methodology of a practical approach to measure liver motion, both respiratory and laparoscopic, with a tool guided in the operating room. AIM Evaluation of the methodology of a practical approach to measure liver motion, both respiratory and laparoscopi...
متن کاملStructured Light Stereoscopic Imaging with Dynamic Pseudo-random Patterns
Structured light stereoscopic imaging offers an efficient and affordable solution to 3D modeling of objects. The majority of structured light patterns that have been proposed either provide a limited resolution or are sensitive to the inherent texture on the surface of the object. This paper proposes an innovative imaging strategy that accomplishes 3D reconstruction of objects using a combinati...
متن کاملHand Motion from 3D Point Trajectories and a Smooth Surface Model
A method is proposed to track the full hand motion from 3D points reconstructed using a stereoscopic set of cameras. This approach combines the advantages of methods that use 2D motion (e.g. optical flow), and those that use a 3D reconstruction at each time frame to capture the hand motion. Matching either contours or a 3D reconstruction against a 3D hand model is usually very difficult due to ...
متن کاملStereoscopic 3d Sports Content without Stereo Rigs
This contribution describes an alternative approach to generate stereoscopic content of sports scenes from regular broadcast cameras without the need for special stereo rigs. This is achieved by using 3D reconstruction previously developed for applications in post-match analysis. The reconstruction method requires at least 4-5 cameras and computes the 3D information automatically. Two different...
متن کاملStereoscopic representation of the breast from two mammographic views with external markers
A new breast imaging technique has been developed and tested for the stereoscopic representation of the breast. The method uses markers at specific locations on the breast surface and standard mammographic projections and was tested with an anthropomorphic phantom containing five mass-like objects at locations determined by a CT scan. The phantom was imaged with a GE Senographe 2000D digital sy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2012