Non echo planar, diffusion-weighted magnetic resonance imaging (periodically rotated overlapping parallel lines with enhanced reconstruction sequence) compared with echo planar imaging for the detection of middle-ear cholesteatoma.
نویسندگان
چکیده
OBJECTIVES We evaluated use of the periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging sequence, compared with conventional echo planar magnetic resonance imaging, in the detection of middle-ear cholesteatoma. MATERIAL AND METHODS Sixteen patients awaiting second-stage combined approach tympanoplasty and three patients awaiting first-stage combined approach tympanoplasty underwent magnetic resonance imaging with both (1) the periodically rotated overlapping parallel lines with enhanced reconstruction sequence (i.e. non echo planar imaging) and (2) the array spatial sensitivity encoding technique sequence (i.e. echo planar imaging). Two neuroradiologists independently evaluated the images produced by both sequences. Radiology findings were correlated with surgical findings. RESULTS AND ANALYSIS Seven cholesteatomas were found at surgery. Neither of the assessed imaging sequences were able to detect cholesteatoma of less than 4 mm. Rates for sensitivity, specificity, and positive and negative predictive values are presented. CONCLUSION Decisions on whether or not to operate for cholesteatoma cannot be made based on the two imaging sequences assessed, as evaluated in this study. Other contributing factors are discussed, such as the radiological learning curve and technical limitations of the magnetic resonance imaging equipment.
منابع مشابه
3T MR imaging of postoperative recurrent middle ear cholesteatomas: value of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted MR imaging.
BACKGROUND AND PURPOSE MR diagnostic of postoperative recurrent cholesteatomas is difficult. Our purpose was to compare multishot fast spin-echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted MR imaging (DWI) with array spatial sensitivity encoding technique (ASSET) single-shot echo-planar DWI and late postgadolinium T1-weighted MR im...
متن کاملValue of Non Echo-Planar Diffusion-Weighted Magnetic Resonance Imaging in the Detection of Middle Ear Cholesteatoma
OBJECTIVE: This study was conducted to determine the clinical value of diffusion-weighted magnetic resonance imaging (MRI) (DWI) in detecting the presence of cholesteatoma. MATERIALS AND METHODS: Fifty-six patients (21 female and 35 male; mean age, 43 years old) who underwent middle ear surgery were referred to the Radiology Department for preoperative DWI study. MRI (1.5-T) was performed using...
متن کاملDiffusion weighted imaging for the detection and evaluation of cholesteatoma
Cholesteatoma is a collection of keratinous debris and stratified squamous epithelium. It is trapped in the middle ear and can lead to bony erosion. The disease is treated surgically often followed by a second-look procedure to check for residual tissue or recurrence. Cholesteatoma has specific signal-intensity characteristics on magnetic resonance imaging with very high signal intensity on dif...
متن کاملSingle-shot, turbo spin-echo, diffusion-weighted imaging versus spin-echo-planar, diffusion-weighted imaging in the detection of acquired middle ear cholesteatoma.
Diagnosis of acquired middle ear cholesteatoma on MR imaging is mostly done on late postgadolinium T1-weighted MR images and/or echo-planar (EPI) diffusion-weighted (DWI) MR images. We describe the appearance of a case of a complicated attical middle ear cholesteatoma on single-shot (SS) turbo spin-echo (TSE) DWI compared with EPI-DWI. This case suggests a higher reliability of SS TSE-DWI in th...
متن کاملFunctional magnetic resonance imaging using PROPELLER-EPI.
Periodically rotated overlapping parallel lines with enhanced reconstruction-echo-planar imaging (PROPELLER-EPI) is a multishot technique that samples k-space by acquisition of narrow blades, which are subsequently rotated until the entire k-space is filled. It has the unique advantage that the center of k-space, and thus the area containing the majority of functional MRI signal changes, is sam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of laryngology and otology
دوره 125 4 شماره
صفحات -
تاریخ انتشار 2011